Technical background: 

 
The  philosophy  behind  Edu-Logger’s  plug  and  play 
technology is based on each sensor’s ability to store its 
own  data  due  to  an  internal  flash  memory  chip  and 
micro-controller  in  each  plastic  Edu-Logger  body.  
This  technology  allows  the  sensor  to  collect  and  then 
store the digital data in the correct scientific units (oC, 
oF, Lux, %, ppm, for example). 
 
The sensor is pre-calibrated at the factory. The built-in 
software  in  the  logger  can  be  upgraded  at  any  time 
using software. 
 
The  flow  sensor  houses  an  internal  water  wheel,  as 
liquid flows through the probe the wheel rotates at the 
same  velocity.    The  water  wheel  does  not  connect 
directly to the walls of the sensor, but instead floats on 
a  bearing  to  lower  the  friction  of  the  system  which 
allows  for  the  water  wheel  to  take  the  velocity  of  the 
water passing through it more accurately.   
 
The  water  wheel  shaft  includes  a  mgnet  and  the 
rotation  is  sensed  by  hall  effect  sensor  without  any 
mechanical connection. 
 
The  flow  is  calculated  by  the  internal  controller  that 
converts the rotation speed into flow rate. 
 

Maintenance and storage: 

 

Summary of Contents for 900-234

Page 1: ...Edu Logger Flow Logger Sensor Guide 900 234...

Page 2: ...done with the 900 234 sensors are stream velocity and health turbidity density verses flow rate fluid pressure and flow relationships and many more The flow sensor uses the following units of measure...

Page 3: ...into the computer Resident PC software and browser based application can be downloaded for free at www edulab com as well as a full software user guide Note Make sure not to download and install both...

Page 4: ...ox to the left of the screen while plugged in 11 To run an experiment and collect data click Run experiment 12 To end data collection early click Stop experiment Tablet smart phone device Materials ne...

Page 5: ...he 900 268 indicator lights will flash take no action until the LED to the far left turns blue this can take up to one minute 7 Take your tablet or smart phone go to the WiFi settings and select the E...

Page 6: ...newer generation 900 268 with the USB icon on the cover this can be used as a 900 213 meaning you can tether the probes directly to the computer using the 900 268 To engage operation in this fashion p...

Page 7: ...uded with the 900 213 module Procedure 1 Connect the flow sensor directly to the left side of a charged 900 215 module 2 When ready to collect data press the Start Stop button on the flow sensor a red...

Page 8: ...4 flow sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the flow sensor to a 900 213 module they directly plug together P...

Page 9: ...resolution 16 bit Resolution 0 0001 m s Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Flow rate probe attached to the sensor body by a durable rubber coat...

Page 10: ...the factory The built in software in the logger can be upgraded at any time using software The flow sensor houses an internal water wheel as liquid flows through the probe the wheel rotates at the sam...

Page 11: ...light Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the product caused...

Page 12: ...12 Thank you for using Edu Logger www edulab com V10012013...

Reviews: