COM Port Settings
Select COM Port
On initialisation the AX200 software will automatically scan COM ports
1 to 4, and display the port it finds. Subsequent initialisations of the
AX200 software will look at the original port address only. Using
Utility
>
Download
you can force the system to rescan all four ports.
Alternatively select
Auto Detect
to scan all ports again.
Ports 1 to 16 can be manually selected if required. Baud rate and parity
settings are automatically configured. The default setting for
Select
COM Port
is
Auto Detect
.
Multiple/Single Card Format
Multiple formats
The AX200 software allows that each cardholder has a unique format.
If selected, then a card type (this includes format and facility code)
should be selected for each cardholder.
Single Format
Normally cards are of the same format and facility code. If cards of the
same technology/manufacturer are used from other systems then
multiple formats can be used. Single format is the default setting.
Default Access Level
This is the access level, which by default shows in the Cardholder screen.
Default
Selecting this will set all the software settings back to factory default.