CMP375 Series
CMP375 Series – Rev. 1.1, Issue 11/07 Page 9 of 12
User's Manual
CONTROL PINS SPECIFICATION
GROUND (KL31)
The GROUND signal is directly
connected to the chassis ground
(Vehicle's ground) as showed.
CAN BUS
The CAN interface has the following
characteristics:
•
CAN V2.0B,
•
Fully isolated from battery
pack potential (SELV)
•
No terminating resistor
ENABLE
The Enable signal puts the charger in
Connected Charging state (DC output
On).
ALARM
LINE PRESENT
CHARGER CONNECTED, D02
Four Open Drain Outputs connect to
GROUND; Imax = 1 amp.
Alarm
indicates when a charger's fault
is detected.
Line Present
indicates when mains
AC input is more that 80Vac.
Charger Connected
signal indicates
when an EVSE Charge Connector is
detected.