CMP375 Series
CMP375 Series – Rev. 1.1, Issue 11/07 Page 6 of 12
User's Manual
CHARGER STATE Definition
The Charger has the following states:
•
NOT CONNECTED – no connection from EVSE to Charge
Coupler is detected (no valid Proximity Detection signal, no
valid Control Pilot signal indicating connection, no valid AC
power is present).
•
CONNECTED STAND-BY – connection detected by Proximity
detection signal or the Control Pilot or AC power on the inlet
connector (J1) but Enable signals (CAN, HW) are not present.
•
CONNECTED CHARGING – the charger provides HV DC
output power.
FAN OUTPUT (V03)
The charger has an electrically floating 24V/1A (V03) used to
supply the FAN assembly.
The FAN assembly is supplied directly by the FAN+ and FAN- outputs.
The fans blow only when the charger is working and the speed
depends by the charger's output current level.
BMS OUTPUT (V02)
The charger provide an +12V/0.1A (V02) output that can be used to
wake up the the BMS unit.
EDN GROUP S.r.l.
Via Mazzini, 10/12 – 20032 – CORMANO (MI) ITALY – TEL. +39 02 66305120 FAX +39 02 61540938
CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL