11 

Installation—Electrical Connection 

STEP 1 

Connect the lead 
coming from the 
AiroMatic fan unit to 
the speed controller 

STEP 2 

Connect the power 
supply lead to the 
speed controller 

STEP 3 

Connect the power 
supply to a mains 
socket. Turn on and 
check fan runs 
freely 

STEP 4 

Using either the 
supplied screws or 
cable ties mount the 
speed controller on a 
suitable piece of 
structure that does not 
place the controller in 
either direct sunlight or 
the airflow of the 
AiroMatic™ 

STEP 5 

Set the control mode by 
pressing the button on the 
side of the speed controller. 

Ensure the power supply is not in contact with 
damp or wet areas 

How the connectors clip together 

Summary of Contents for AiroMatic

Page 1: ...Product Manual...

Page 2: ...es Cordless Drill Screwdriver Marker Pen Foil Tape Sarked Roofs Only Knife Sarked Roofs Only Tek Screws or Sealed Rivets x 10 Metal Roof Only Nibbler or Similar Cutting tool Metal Roof Only Included P...

Page 3: ...er speed controller and power supply Important Notices and Warnings WARNING Do not proceed with the installation until you have read the entire instructions including these warnings Install at your ow...

Page 4: ...cut the tiles to provide clearance Installation Tiled Roof The removal of a tile higher than this may damage the integrity of the ridge tile pointing and is NOT recommended STEP 2 If the roof is sarke...

Page 5: ...d sides of the flashing into the shape of the tiles Make sure that the cable is through the opening and not caught under the flashing STEP 3 Taking the Airomatic unit slide the flashing under the tile...

Page 6: ...he side and front edges of the flashing STEP 6 From within the roof space fit the fixing strap by hooking it between the flashing up stand and the outer housing The fixing strap should be hooked near...

Page 7: ...formed as required to achieve this For additional weather proofing turn the rear edge of the flashing up so that it seals against the tiles above Installation Tiled Roof Turning the rear of the flashi...

Page 8: ...pping Mark the centre of each side to determine where the centre of the vent will be Ensure the flashing covers the corrugations or ribs equally and that it is located between the roof joists STEP 2 R...

Page 9: ...ng under the ridge capping Line up the centre marks made earlier to ensure that the vent is centred on the opening Ensure that the cable is through the opening and not caught under the flashing STEP 4...

Page 10: ...flashing following the edge along the three exposed sides STEP 6 Secure the flashing to the metal sheeting with Tek screws or sealed rivets along the 3 exposed edges of the flashing Approximately 10...

Page 11: ...et Turn on and check fan runs freely STEP 4 Using either the supplied screws or cable ties mount the speed controller on a suitable piece of structure that does not place the controller in either dire...

Page 12: ...he appropriate speed MODES LO Default Continuous operation low speed low flow rate very quiet very low power consumption MED Continuous operation moderate speed moderate flow rate HI Continuous operat...

Page 13: ...arks or scratches STEP 2 Remove the 4 screws securing the flashing to the Airomatic housing Remove flashing from Airomatic being careful not to damage the cable WARNING Do not disassemble the Airomati...

Page 14: ...rews securing it Be careful to prevent the housing from dropping away as the screws are removed STEP 4 Paint Airomatic housing and flashing and allow to dry The plastic used for the Airomatic housing...

Page 15: ...ace Check that the fan blades rotate freely and are not impeded All screws should be hand tightened until snug Do not over tighten screws as this may cause them to strip out of the plastic STEPS 5 6 7...

Page 16: ...VDC Fan Motor Electronic Commutating EC motor Input Voltage 24 VDC Protection Class IP54 Speed Control Type Temperature Humidity Sensing Electronic Variable Speed Controller Input Voltage 24 VDC Fixe...

Page 17: ...Product Dimensions Speed Sound Pressure Level SPL LA psF 0 dB A Max running power consumption W Flow rate qv psF 0 m3 hr LO 35 4 4 291 MED 45 1 12 434 HI 52 9 30 647 NOTE Sound pressure level measure...

Page 18: ...le then an electrician will be required to install one Q Can I wire it directly into the mains power A No you must use the supplied power supply and speed controller for the Airomatic to work correctl...

Page 19: ...ralia www edmonds com au Contact Details General Enquiries and Support PH 1300 858 674 Email Sales edmonds com au Technical Ventilation Enquiries PH 61 2 8824 0444 March 2017 I 040 B Please fill out f...

Page 20: ...edmonds com au...

Reviews: