38
Other functions
You can specify the M-10DX’s sampling frequency.
If you’re outputting a digital signal from the M-10DX’s
DIGITAL OUT jack, the M-10DX’s sampling frequency and
the sampling frequency of the device receiving that digital
signal must be set to the same setting.
You can select the sensor used by the Room Acoustic Control
function.
Before you switch from CH1 to Built-in, you must disconnect
the mic that‘s connected to channel 1. If you fail to disconnect
the mic, a feedback loop may occur, possibly damaging your
speakers.
If you select CH1, channel 1 will not function as a mixer
channel.
In this case, the indication “RAC” is shown in the channel 1
position of the level meter screen.
fig.Func-CH1
If you turn the channel 1 EQ knobs or press the [SEL] button,
the following message will appear.
fig.Func-CH1-Caution
You can specify the lower and upper limits of the frequency
range that is automatically analyzed by Room Acoustic
Control.
If you’re using a mic connected to channel 1 as the sensor for
Room Acoustic Control, adjusting this setting as appropriate
for the frequency response of your mic will allow the
adjustment to occur more optimally.
* If the function switch is set to “INT,” use the following settings:
RAC Freq >= 40 Hz
RAC Freq <= 16 kHz
If you’re operating the M-10DX on batteries, you must specify
the type of batteries you’re using.
If you’ve specified a type of battery that's different than the
batteries actually installed in the M-10DX, the remaining
battery power will not be shown correctly, and battery life
may be affected.
The pre-fader signals (from before the channel LEVEL knob)
of channels 1 and 2 can be output to DIGITAL OUT.
Specifying the M-10DX’s sampling
frequency (Sample Freq)
Setting
44.1, 48, 96 (kHz)
Selecting the Room Acoustic Sensor
(RAC Source)
Setting
Explanation
Built-in
Use the sensor built into the M-10DX.
CH1
Use the mic connected to channel 1 as the
sensor.
Specifying the frequency range
analyzed by Room Acoustic Auto
Control (RAC Freq >= / RAC Freq <=)
Parameter
Range
RAC Freq >=
(lower limit)
25, 40, 63, 100 Hz
RAC Freq <=
(upper limit)
10, 16, 20 kHz
Selecting the type of batteries
(Battery)
Setting
Explanation
Alkaline
Alkaline battery
Ni-MH
Nickel metal-hydride
Digitally outputting the pre-fader signal
of channels 1 and 2 (REC to D.OUT)
Setting
Explanation
OFF
The same signal as the output of MAIN OUT
jacks will be sent from the digital output.
ON
The pre-fader signal of channels 1 and 2 will be
sent from the digital output.