fig.RAC-Rstart
When the L channel analysis and adjustment have been
completed, the analysis will proceed to the R channel.
Raise the output level if the screen indicates “Turn Up
Level,” or lower the output level if it indicates “Turn Down
Level.”
When the sensor/mic detects the test signal, the screen will
indicate “Measuring,” and analysis of the R channel will
start.
Finishing the adjustment
fig.RAC-14
When analysis and adjustment have been completed for both
channels, the [ROOM ACOUSTIC] button will change from
blinking to lit, and the screen will show the result of the
adjustment.
When the adjustment has been completed, the input channels
will be unmuted, and the M-10DX will return to normal
operation.
8.
Listen to the adjusted sound.
The frequency response curve and its amplitude is stored together with the adjustment results (graphic
equalizer settings) as a set. (This is remembered even when the power is turned off.)