7
16�
Remote input monitor connector indicates at -6dB input level
Pin 4+5 (5=GND) = LED connection , indication/diagnostic test
17�
Remote Output Monitor Connector indicates at 0 dB output level
Pin 5+6 (5=GND) = LED connection, indication/diagnostic test
B.
INPUT 3 (PHOENIX SCREW TERMINAL/RCA)
18� Balanced Line: 30 mVrms-5Vrms (-28dBu to 17dBu)
19�
Unbalanced RCA left/right
C.
INPUT 2 (PHOENIX SCREW TERMINAL)
Switchable between line and 50-100V speaker line input
Note:
The speaker line MUST be balanced at the Phoenix connector (connect (+) and (–) terminal)
Use earth ONLY for free-floating screen or leave unconnected
20�
Speech filter: Low cut filter 130-170Hz On/Off
Speech Enhancement (Flat/Speech) attenuates low frequencies (<150Hz) increasing speech
intelligibility for microphone use
Note:
When commissioning field strength level and frequency response this feature must be
switched to Flat postition
21�
Speaker 50-100V balanced Line, sensitivity On/Off
Caution!
50-100 V/Line must be set prior to any further settings
22�
Override/Priority function mutes inputs and is typically used for voice alarm systems� Signals higher
than -6dB on input 2 activates the priority function
23�
Balanced Line: -15dBu (50mVrms) to +20�6dBu (8�3Vrms)
D.
INPUT 1 (BALANCED XLR)
Balanced XLR� Switchable between Line and Mic sensitivity and with or without Phantom voltage
Note:
With unbalanced connection (not recommended) the pin not used should be grounded�
24�
Speech filter: Low cut filter 130-170Hz, On/Off
Speech Enhancement (Flat/Speech) attenuates low frequencies (<150Hz) increasing speech
intelligibility for microphone use
Note:
When commissioning field strength level and frequency response this feature must be
switched to Flat position
25�
Line/Mic sensitivity switches: -55dBu (1�5 mVrms) to +10dBu (2�6Vrms)
26�
Phantom voltage 12V, On/Off
27�
Balanced XLR