INSTRUCTIONS FOR USE

A

2

1

3

4

AIR CONTROL

AIR CONTROL

Shifting the air limiter lever allows for regulating the amount of combustion air entering the combustion chamber and

Shifting the air limiter lever allows for regulating the amount of combustion air entering the combustion chamber and
post combustion

post combustion

Description

Effect

Position 1

Ignition / maximum 
power

Primary air sent entirely to the combustion chamber plus turbo air (all to the RH)

Primary air sent entirely to the combustion chamber plus turbo air (all to the RH)

Position 2

Intermediate

Primary air completely open

Position 3

Intermediate

Primary air half

Position 4

Ember maintenance

Post-combustion air only

Post-combustion air only
All passages for the primary combustion air are closed (all to the LH)”

All passages for the primary combustion air are closed (all to the LH)”

Summary of Contents for WINDO 100

Page 1: ...WINDO 70 WINDO 90 WINDO 100 WINDO120 UK Installation use and maintenance WOOD FIREPLACE ...

Page 2: ...0 Dop 182 WINDO 90 Dop 187 WINDO 100 Dop 189 WINDO120 Dop 190 Not all versions are available for all countries The liability of Edilkamin is limited to the product supply only The original language of this manual is Italian TABLE OF CONTENTS Safety information 4 Safety information 4 Introducing the range 5 Introducing the range 5 General information General information Technical data Dimensions Te...

Page 3: ... the product If you lose it you can request a copy or download it from www edilkamin com After unpacking the product check the condition and completeness of the contents In the event of error immediately contact the retailer where the purchase was made providing him with a copy of the warranty booklet and the sales receipt The appliance must be installed and operated in compliance with local and n...

Page 4: ...C OR ANYTHING OTHER THAN DRY WOOD IN THE FIREPLACE You risk dirtying the product fires in the chimney flue and causing damage to the environment use of fuel different from the recommended fuel DO NOT OVERLOAD THE FIREPLACE There is a risk of deformation with risks for people in the event of attempted fixing up and irreversible changes to the colour of the paint on the metal parts Edilkamin or the ...

Page 5: ... of several models Windo 70 N Windo 90 N Windo 100 N Windo 120 N models can be ventilated with 3 distinct accessories ask the dealer A SIDE VENTILATION KIT with regulator and remote control B AIR DIFFUSER KIT C ventilated air vents INTRODUCING THE RANGE A B C ...

Page 6: ...able volume 375 460 470 500 m3 Smoke outlet pipe diameter 180 mm Weight including packaging 220 250 380 430 kg Energy efficiency class accor ding to UE 2015 1186 regula tion Class A G A A A A TECHNICAL DATA FOR THE DIMENSIONING OF THE FLUE WINDO 70 WINDO 90 WINDO 100 WINDO 120 Nominal power Temperature of fumes on exit from the discharge pipe 302 285 313 313 C Minimum draught 10 10 10 10 Pa Fume f...

Page 7: ... 70 WINDO 90 dimensions cm glass dimensions 70x51 Windo70 glass dimensions 90x67 Windo 90 53 13 18 35 34 26 Ø 18 cm 50 135 153 10 5 93 113 70 90 51 67 smoke outlet Ø 14 cm without kit Air difffuser Ø 10 cm with kit Air difffuser ...

Page 8: ...mensions cm glass dimensions 100x51 Windo 100 glass dimensions 120x51 Windo 120 DIMENSIONS 135 10 51 35 18 13 53 100 120 123 143 53 34 123 58 7 58 7 Ø 18 cm smoke outlet Ø 14 cm without kit Air difffuser Ø 10 cm with kit Air difffuser ...

Page 9: ... THE PRODUCT FROM THE PALLET Detach the product from the pallet by loosening the screws A securing it to the latter and located on the feet Remove Detach the product from the pallet by loosening the screws A securing it to the latter and located on the feet Remove the product from the pallet while being careful to protect the door and its glass panel from mechanical impacts which the product from ...

Page 10: ...Insert two tubes through the rings USE THE WHEELS ONLY FOR SMALL USE THE WHEELS ONLY FOR SMALL MOVEMENTS DO NOT DRAG THE MOVEMENTS DO NOT DRAG THE PRODUCT THE FEET MAY GET PRODUCT THE FEET MAY GET DAMAGED DAMAGED USE THE WHEELS after screwing the USE THE WHEELS after screwing the feet on feet on Make sure that the product remains balanced during handling B PLEASE NOTE If the fireplace is not level...

Page 11: ...astening it with the screws or as a detachable handle using the relevant bushes Side cover of the casing 5 2 to be screwed on once the chimney has been positioned and the lifting brackets have been removed Tighten the 4 4 screws and close the opening with the side cover of the casing 2 3 xxxxx 4 5 PACKAGING The packaging includes a useful inspection hatch to check the status of the product On rece...

Page 12: ...ISH INSTALLATION LOOSEN THE LOCKING SCREWS ON THE SIDES IN ORDER TO LIFT THE DOOR LOOSEN THE SCREWS ONLY AFTER THE PRODUCT HAS BEEN POSITIONED DO NOT SHIFT THE PRODUCT WITHOUT THE LOCKING SCREWS locking screws ...

Page 13: ...ct is delivered only with the fire beds installed the deflector E is not mounted Assembly sequence for REFRACTORY ELEMENTS 1 Position the LH SIDE element 2 Position the BOTTOM element 3 Position the RH SIDE element 4 Position the deflector E A 2 3 4 E A A B Il diametro dell uscita fumi non è il diametro del sistema camino che dovrà essere dimensionato Fit the sides first and then the bottom on win...

Page 14: ... one or more plates P must be applied to the inner frame for the door To make the door self closing one or more plates P must be applied to the inner frame for the door To access the inner frame for the door remove the flap located on the fireplace s casing To access the inner frame for the door remove the flap located on the fireplace s casing without plates standard with plates added during the ...

Page 15: ...e general instructions below however We give some general instructions below however these do not obviate the need to comply with local these do not obviate the need to comply with local regulations and do not affect the installer s liability for regulations and do not affect the installer s liability for the installation the installation Checking the suitability of the installation premises The v...

Page 16: ...ace present Check on the chimney system s data plate the safety distances to be kept in the presence of combustible materials and the type of insulating material to be used The product must be installed in accordance with the following safety instructions dimension mm Windo 70 Rear 200 Sides 300 Front 800 Windo 100 Rear 300 Sides 350 Front 1800 Windo 90 Rear 200 Sides 300 Front 800 Windo 120 Rear ...

Page 17: ...oduced by combustion Before positioning the product you need to check the chimney flue is suitable SMOKE CHANNEL CHIMNEY FLUE SMOKE CHANNEL CHIMNEY FLUE The smoke channel pipe that connects the smoke outlet of the fireplace with the chimney flue inlet and the chimney flue must along with other legal provisions receive the discharge for a single product multiple product discharges are not permitted...

Page 18: ...ve a radius under 20 mm and a ratio between between the inner dimensions 1 5 normally have a minimum height of 3 4 metres maintain a constant section be waterproof and thermally insulated to guarantee draft preferably create a collection chamber for unburned fuel and any condensate be at least category T400 with an adequate resistance to soot fireIf pre existing it must be cleaned to avoid risk of...

Page 19: ...able for the external air intake In accordance with local regulations the air intake can be mounted outside or in suitable rooms not subject to depression The cladding must have the grille at floor level so that combustion air can enter the product OPTIONAL FEATURES Kit for the direct connection of the combustion air intake Contacteur el revendeur ...

Page 20: ...nged along a straight line as far as possible The aluminium pipes can be concealed with boxes false beams or built into the walls regardless of the chosen solution they must be adequately insulated boxes false beams or built into the walls regardless of the chosen solution they must be adequately insulated The length of the ducting depends on the product s insulation and manner of use The length o...

Page 21: ...SAFELY TO AN EARTH CONTACT IN ACCORDANCE WITH THE REGULATIONS IN FORCE INSTALLATION Circulation with Kit Air Diffuser The vents are not included in the Air Kit Diffuser and you can choose the one of the four models available and described which best suits your needs at the retailer The adjustment is made through a control unit and a remote control ...

Page 22: ...IDE VENTILATION KIT with regulator and remote control Contents air box fan electronic regulator 2 way fitting 2 R2 flanges compatible pipe for outdoor air intake Ø 14 code 76790 Automatic operation manual start temperature probe and remote control ...

Page 23: ...e placed against one panels which must not be placed against one another but spaced at least 1 cm apart to enable air another but spaced at least 1 cm apart to enable air to flow and prevent heat build up The gather hood to flow and prevent heat build up The gather hood can be made with fireproof panels plasterboard can be made with fireproof panels plasterboard or gypsum slabs during construction...

Page 24: ...ox s frame and the cladding itself If purchased it is sold in a single package If purchased it is sold in a single item containing the frame itself 1 n 6 screws 2 To assemble it secure the brackets to the fireplace structure tighten the screws Internal dimension Windo 70 cm 72x55h Windo 90 cm 92x71h Windo 100 cm 102x55h Windo 120 cm 122x55h 2 1 ...

Page 25: ... use the fixed handle or the With the handle the Edilkamin system allows the user to choose whether to use the fixed handle or the detachable handle detachable handle BOTTOM HUNG DOOR OPENING BOTTOM HUNG DOOR OPENING To open the door with the bottom hung system adjust the levers to the right and left of the To open the door with the bottom hung system adjust the levers to the right and left of the...

Page 26: ...stion Description Effect Position 1 Ignition maximum power Primary air sent entirely to the combustion chamber plus turbo air all to the RH Primary air sent entirely to the combustion chamber plus turbo air all to the RH Position 2 Intermediate Primary air completely open Position 3 Intermediate Primary air half Position 4 Ember maintenance Post combustion air only Post combustion air only All pas...

Page 27: ...e the smoke the fireplace needs a draft to be exerted on the smoke the fireplace needs a draft to be exerted on the chimney flue chimney flue If the draft is weak initially light a starter fire using If the draft is weak initially light a starter fire using small sized lighting material small sized lighting material Once the correct draft is restored you can add the fuel Once the correct draft is ...

Page 28: ... NOTES ON REFRACTORY MATERIAL The inner refractory material was designed to resist normal use Its cleaning is ensured by good combustion The main damage to refractory material comes from accidental knocks use of firelighters which are not ecologicalloading wood beyond the recommended amount use of fuel other than that recommended Edilkamin or the retailer cannot be held liable for damage caused as...

Page 29: ...a scoop or ash cleaner Remove the ash using a scoop or ash cleaner Place the removed ash exclusively in non combustible Place the removed ash exclusively in non combustible containers bear in mind that the residual embers may containers bear in mind that the residual embers may still re ignite 24 hours after the last combustion still re ignite 24 hours after the last combustion Ceramic glass insta...

Page 30: ...m on the glass 4 If the chimney flue catches fire or you need to suddenly extinguish the fire lighting in the fireplace if possible in safe conditions remove the ash and brazier using tools and only touch metal containers with fireproof gloves in the event of a fire ask the authorities for help 5 In case of odours check if If first switch on in this case a paint smell is normal If the product is d...

Page 31: ......

Page 32: ...cod 942109 GB 07 20 A w w w e d i l k a m i n c o m 942109 GB ...

Reviews: