46
ENGLISH
TROUBLESHOOTING
USER/INSTALLER
LACK OF COMMUNICATION:
If there is prolonged lack of communication between the product and the remote control, the ‘no network’ icon
appears (barred aerial) and the room temperature, time and day of the week remain visible.
The Power at level 1 is displayed if the product was in Automatic/Crono, whereas at the previously set level, if it was
in Manual. Ventilation remains at the last display.
If the lack of communication occurs during navigation through the Menus, it automatically goes back to the main
display.
PELLET RESERVE INDICATOR:
The function is only available if the pellet level sensor is installed and has been activated. When the level sensor
triggers, the circuit board emits a single “beep” (in any switch-on or ON status) and the “PLT” symbol indicating the
reserve appears on the display.
After an interval of roughly 20-40 minutes, which varies depending on the model, the stove switches off due to a
shortage of pellets, maintaining the PLT symbol.