![EdilKamin RADA AIR TIGHT C Installation, Use And Maintenance Manual Download Page 20](http://html1.mh-extra.com/html/edilkamin/rada-air-tight-c/rada-air-tight-c_installation-use-and-maintenance-manual_2360756020.webp)
20
ENGLISH
USER
USER INSTRUCTIONS
Fig. 1
Fig. 2
Fig. 3
The display reads the
POSSIBLE STATES
described below:
- OFF STATE
The product is shutting down or is off in response to
a manual switching off by using the ON/OFF button
of the remote control or due to an external contact
(crono, phone dialler)
The display shows the current time, room temperature
and the status in relation to which the product is OFF.
The product is OFF:
due to manual operation of the user (fig. 1)
due to power failure (fig. 2)
due to shut off by Crono mode (fig. 3)
From the OFF screen, press the ON/OFF button for 3
seconds to switch to the ON screen.
Pressing the +/- keys has no effect.
Pressing the M key displays the menu.
- ON STATE
The product is ON.
The display shows (figure 4)
1. the current time
2. the current room temperature
3. the room temperature setting or manual mode
4. the power level (represented by the flames)
5. the fan level (represented by the filling in of the
blades)
If timer programming is active, 3 and 4 are replaced by
the day’s timer programming with the current setpoint
at the centre (figure 5) and the temperature displayed
at the top right.
- ALARM STATE
In case of shutdown due to alarm, 4 is replaced by a
message indicating the type of shutdown (figure 6)
- STAND BY STATE
Situation in which there is no demand for heating.
If the Stand By function is active, the display shows the
same information as in the ON state without flame (on
the top left you will see “STB”).
Fig. 4
Fig. 5
H1
Fig. 6
While in stand-by mode, and ON, the
product turns on only if there is a heat
request