19
ENGLISH
USER INSTRUCTIONS: STAND BY
USER
- Stand by
When the Stand by function is active, in automatic
and crono mode, the product shuts off when the
temperature setpoint is reached and turns on again
when the room temperature drops.
When the Stand By function is not active, the product
sets itself to minimum power when the temperature
setpoint is reached.
NOTE visible only if the product is in “automatic” mode.
The product is programmed by default with a delta of +/- 1°C to optimise comfort.
The technician can change this setting during commissioning to suit the needs of the application.
The display shows the temperature rounded down. This means that 20.1°C and 20.9°C are indicated as
“20°”.
For example, with the room temperature set to 20°C, the product will enter the modulation mode/switch off
when a temperature of 21 C is reached and will switch on again below 19 C.