EdilKamin GORA 22 Installation, Use And Maintenance Manual Download Page 24

24

ENGLISH

From the OFF screen, press and hold the ON/OFF button to go to the ON screen.

ON MODE

The product is “active” and can produce heat. The product can be on/in ignition.
 The display shows
•  the current time
•  the current room temperature (top number in the main area)
•  the set room temperature (bottom number in the main area)
•  the power level (represented by the flames)
•  the fan level (represented by the filling in of the blades)
If the timer programming is active (Crono), the text “TIMER” appears on the right.
The figure below shows the various possibilities.

OPERATIONAL LOGIC

On without heating demands (Stand By Off)

On with heating demand

On with thermostat Off (Stand by Off)

On with thermostat demand

On with Timer (Stand by Off)

On with Timer

On with domestic hot water demand

Summary of Contents for GORA 22

Page 1: ...GORA 22 GORA 26 GORA 29 EN Installation use and maintenance pag 2 PELLET BOILER...

Page 2: ...NO Data plates Declaration of Conformity Rating plate reference Moreover the company hereby declares that the GORA 22 GORA 26 GORA 29 wood pellet stove satisfy the requirements of the following Europe...

Page 3: ...warranty certificate accompanying the product In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure best results from the product Th...

Page 4: ...roduct may be soiled the flue may catch fire and could cause damage to the environment cleaning the hearth when hot NEVER VACUUM WHEN HOT This risks damage to the vacuum cleaner and smoke in the room...

Page 5: ...Vac 5x20 TECHNICAL CHARACTERISTICS in accord with EN 303 5 GORA 22 GORA 26 GORA 29 GORA 22 26 29 Nominal power Nominal power Nominal power Reduced power Heat input 21 5 25 8 29 2 6 kW Available power...

Page 6: ...ensions cm 55 78 131 131 78 97 1 27 5 17 1 16 Smoke outlet 8 cm 42 7 24 6 27 5 Combustion air 5 cm A A Hydraulic connections depend on the optional kits R FX R2 FX o RW FX You can find further informa...

Page 7: ...no Combination boiler no Fuel Preferred fuel only one Other suitable fuel s s Seasonal space heating emissions PM OGC CO NOx mg m 3 at 10 O2 Log wood moisture content 25 no no Chipped wood moisture c...

Page 8: ...At 30 50 of rated heat output if applicable p 88 2 For solid fuel cogeneration boilers Electrical efficiency Auxiliary electricity consumption At rated heat output elmax 0 073 kW At rated heat output...

Page 9: ...no Combination boiler no Fuel Preferred fuel only one Other suitable fuel s s Seasonal space heating emissions PM OGC CO NOx mg m 3 at 10 O2 Log wood moisture content 25 no no Chipped wood moisture c...

Page 10: ...At 30 50 of rated heat output if applicable p 88 2 For solid fuel cogeneration boilers Electrical efficiency Auxiliary electricity consumption At rated heat output elmax 0 090 kW At rated heat output...

Page 11: ...r no Combination boiler no Fuel Preferred fuel only one Other suitable fuel s s Seasonal space heating emissions PM OGC CO NOx mg m 3 at 10 O2 Log wood moisture content 25 no no Chipped wood moisture...

Page 12: ...At 30 50 of rated heat output if applicable p 88 2 For solid fuel cogeneration boilers Electrical efficiency Auxiliary electricity consumption At rated heat output elmax 0 090 kW At rated heat output...

Page 13: ...water to the boiler stove must be higher than 50 55 C to prevent the forming of condensation An accumulator tank is needed to heat lowtemperature radiant panels and must be installed according to the...

Page 14: ...2 5 6 0 172 7 1 5 7851 0 1 7 5 6 0 172 7 1 9 5 6 5 2 6 85 6 85 7 6 5 5 144 mm 73 mm R2 FX 48 672 25 2 17 3 9 0 172 7 6 17 6 7 225 2 5 2 2 2 27 2 62 2 3 5 21 25 7 5 5 72512 5 6 0 172 7 1 5 7851 0 1 7 5...

Page 15: ...e falls 1 C below the set temperature the flow switch when the DHW tap is opened The heat demand is shown on the display by a radiator or a tap symbol COMBINATION WITH ACCUMULATOR TANK The Kits combin...

Page 16: ...nal unit for drawing pellets must be fixed to the plate D see system technical diagram ADAPTATION FOR PELLET LOADING SCREW SYSTEM optional The boiler is designed for pellet loading by means of a screw...

Page 17: ...nstaller s liability for regulations and do not affect the installer s liability for the installation the installation Checking the suitability of the installation space The floor must be able to bear...

Page 18: ...the other it must extend beyond the back flow zone in Italy refer to UNI 10683 point 6 5 8 it must allow for maintenance of the chimney EXTERNAL AIR INTAKE In general we suggest two ways to ensure a...

Page 19: ...EN 1856 and EN 1457 The installer must observe both these and any other local regulations This manual should not in any way be considered as a replacement for existing regulations The product must be...

Page 20: ...nput e g for a second probe for accumulator tank or boiler for domestic hot water or for an external probe for climatic curve 3 4 NTC probe accumulator tank thermostat 5 6 NTC probe room thermostat th...

Page 21: ...it is not used Press any button to activate it again You are now asked to confirm or set the Time and Date Set the values with the keys and confirm with OK The day of the week is calculated automatica...

Page 22: ...button on the display to activate the boiler stove and adjust the desired room temperature with the buttons The boiler stove will switch on and off and will adjust its power automatically to keep the...

Page 23: ...tatus in relation to which the product is OFF The product can be in the OFF mode in these cases due to manual operation of the user with probe due to manual operation of the user with thermostat due t...

Page 24: ...rature bottom number in the main area the power level represented by the flames the fan level represented by the filling in of the blades If the timer programming is active Crono the text TIMER appear...

Page 25: ...see STB The LCD shows the following information product mode STB the current time the room temperature or the mode of the room thermostat the activation of the timer programming if present Timer Crono...

Page 26: ...automatically to keep the set temperature By pressing the M button you access the Menu screen Accessing the Menus you can set the following described on the following pages Stand By Crono PROGRAM Temp...

Page 27: ...inimum power when the temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the functi...

Page 28: ...function from the main menu press the M button Scroll using the buttons and select the function by pressing OK To select ACTIVATE press OK Use the buttons to select On Off i e activate deactivate the...

Page 29: ...he start and end of the time period to which you wish to apply the chosen temperature level This is done in steps of 30 The buttons have the following functions move the cursor indicating the time for...

Page 30: ...ono press the OK button to enter the DISPLAY function The buttons have the following functions to scroll through the days ahead to scroll through the days back OK return to the previous menu M return...

Page 31: ...ton Choose the option with the buttons press OK to change the setting You can set the water temperature in the boiler stove BOILER on the display In presence of external probe the water temperature is...

Page 32: ...e buttons and select the function by pressing OK Use the buttons to activate deactivate the function Press M to quit without saving Confirm by pressing the OK button for 2 seconds Language Selects the...

Page 33: ...nction by pressing OK Use the buttons Press M to quit without saving Confirm by pressing the OK button for 2 seconds VARIOUS MENUS Info These readings should only be done when requested by the technic...

Page 34: ...tenance will immediately void the warranty When cleaning is necessary the message Clean exchanger will appear on the panel if further cleaning is necessary If the exchanger needs cleaning the message...

Page 35: ...residue out into the ash pan Scrap the combustion chamber with the spatula provided removing any obstructions in the openings DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER Take out and empty th...

Page 36: ...CHANGERS ALSO WHEN THE STOVE IS LIT USING THE GLOVE Shake the cleaning handle positioned under the pellet loading cover 5 fig D NEVER SUCTION HOT ASH as this could da mage the suction device and possi...

Page 37: ...n original spare parts may damage the appliance and relieves Edilkamin of all liability for damage that may arise from doing this Do not make unauthorised modifications DISPOSAL At the end of its serv...

Page 38: ...are two possibilities NO flame Check that the grate is seated properly and is clean Check that there are pellets in the tank and grate Use a piece of solid paraffin to light the stove contact the tec...

Page 39: ...the technician H11 Switching OFF due to the inter vention of the safety pressure switch Ensure the stove and flue are clean Contact the technician H12 Room temperature probe failure Contact the techn...

Page 40: ...ed by an authorised Edilkamin technician WATER OVERHEATING SHUT DOWN WITHOUT ALARM If the water in the boiler stove reaches a temperature of 85 C the boiling stove shuts down without switching to alar...

Page 41: ...as been tripped it must be reset using the reset button behind the boiler after having removed the protective cap A A SAFETY THERMOSTAT If pellet loading fails especially after a power failure check w...

Page 42: ......