background image

48

IT

ALIANO

USER

USER INSTRUCTIONS

- DATE AND TIME

Can be used to set the current date and time.

The hours will then flash and can be modified using the 

 and 

 buttons 

with the 

 button the minutes will then flash.

To access the function from the main menu (as indicated in the Menu paragraph above), press the 

 button. 

You can scroll the menu items with the 

 and 

 buttons and enter the item with the following button 

 

After entering the Date-Time function, the display will show the name of the function on the first line of the status bar 
and the current value of the first setting (12/24 hours) on the second line.  

You can switch from 12 to 24 hours using the 

 and 

 buttons and confirm with the following button 

 

M

®Ä—

T

«›

M

®Ä—

T

«›

14.9

°

C

14.9

°

C

15:36

15:36

05

05

DATE-TIME

24 HOURS

DATE-TIME

DAYLIGHT SAVING 

TIME: OFF

Summary of Contents for BLADE2 H 18 UP

Page 1: ...BLADE2 H 18 UP BLADE2 H 22 UP For all updates visit www edilkamin com PELLET BOILER STOVE EN Installation use and maintenance page 2...

Page 2: ...trademark named BLADE2 H 18 UP BLADE2 H 22 UP SERIAL NO Rating plate reference BLADE2 H 18 UP Dichiarazione di prestazione DoP EK n 218 BLADE2 H 22 UP Dichiarazione di prestazione DoP EK n 219 Moreov...

Page 3: ...y do not always strictly refer to your specific model and are not binding in any way MEANING OF SYMBOLS In some parts of the manual the following symbols are used INFORMATION failure to comply with th...

Page 4: ...those that are subject to fire risks DO NOT INSTALL THE PRODUCT IN AREAS SUBJECT TO THE RISK OF FIRE contact with fire and hot parts e g glass panel and pipes DO NOT TOUCH HOT PARTS and when the stov...

Page 5: ...nd air intakes in the room DO NOT BLOCK THE AERATION VENTS OR FLUE Risk of smoke returning into the room with consequent damage and injury use of the product as a support or ladder DO NOT CLIMB ONTO T...

Page 6: ...120 5 39 71 7 5 5 cm combustion air 8 cm male smoke outlet with optional element 10 25 5 71 61 The boiler stove is supplied standard with the top smoke outlet female An optional kit is available for...

Page 7: ...outlet 7 71 7 5 5 cm combustion air 8 cm smoke outlet with optional element 10 25 5 71 61 18 space for housing the R R2 or RW Blade H22 hydraulic kit Information on the kit manual The boiler stove is...

Page 8: ...r 50 mm Weight including packaging 307 259 kg Energy efficiency class Regulation 1185 2015 Classi A G A TECHNICAL DATA USER INSTALLER EDILKAMIN S p A reserves the right to modify the product at its ow...

Page 9: ...nale Potenza Ridotta Temperatura uscita fumi allo scarico kW Tiraggio minimo 0 01 Pa Portata fumi 15 5 14 2 6 7 g s Emissione CO2 11 6 10 5 5 9 ELECTRICAL SPECIFICATIONS BLADE2 H 22 UP BLADE2 H 18 UP...

Page 10: ...ALIANA CAMINI LAYMA2 IDRO 22 Indirect heating functionality YES Direct heat output 3 8 kW space heat output Indirect heat output 19 0 kW water heat output Fuel Preferred fuel only one Other suitable f...

Page 11: ...A2 H 18 UP ITALIANA CAMINI LAYMA2 IDRO 18 Indirect heating functionality YES Direct heat output 3 7 kW space heat output Indirect heat output 15 5 kW water heat output Fuel Preferred fuel only one Oth...

Page 12: ...ring disposing of The end user is responsible for storing disposing of and recycling them in a regulatory fashion and recycling them in a regulatory fashion Always move the stove in an upright positio...

Page 13: ...stoves have adjustable feet to adapt to uneven floors The feet can be adjusted by slightly raising the boiler stove or using a screwdriver from above the foot WALL MOUNTING Mount the stove to the wal...

Page 14: ...cy of the system Edilkamin recommends an accumulator of at least 20 l kW The return temperature of water to the boiler stove must be higher than 50 55 C to prevent the formation of condensation An acc...

Page 15: ...15 ITALIANO WATER CIRCUIT INSTALLATION R2 KIT Hydraulic connections template in mm 129 232 127 62 99 74 3 4 M 3 4 M 1 2 M INSTALLER...

Page 16: ...16 ITALIANO WATER CIRCUIT INSTALLATION INSTALLER R RW KIT Hydraulic connections template in mm 257 197 127 62 76 114 3 4 M 1 2 M 1 2 M 3 4 M 1 2 M...

Page 17: ...e to use commercial elbows and exploit the recess indent between the pipes outlet and the rear of the stove as shown in the figure below WATER CIRCUIT INSTALLATION When installing the kit remove the r...

Page 18: ...I 10683 standard the appliance can also be installed in bedrooms or in rooms which already include a product that takes in combustion air from the same room provided that the air inlet is connected to...

Page 19: ...sky be made of material rated fire reaction class A1 per UNI EN 13501 or analogous national regulations be appropriately certified with a suitable chimney plate if made of metal maintain the same cros...

Page 20: ...other must extend beyond the back flow zone in Italy refer to UNI 10683 point 6 5 8 must allow for maintenance of the chimney EXTERNAL AIR INTAKE In general we suggest two alternative ways for ensuri...

Page 21: ...ONNECTIONS the power socket must be located in an easy to access position The stove is equipped with an electrical power cord or connection to a 230V 50 Hz socket preferably with an electromagnetic sw...

Page 22: ...k a 8 Countersunk hex screw M5x16 b 18 Self tapping screw 4 2x9 5 c 9 The above mentioned elements once they have been mounted will be positioned exploded as shown in the figure The above mentioned el...

Page 23: ...NOT TIP OVER Assembling the left hand side panel 1 and 2 Screw on the bottom left hand side panel the external left hand profile and the left hand front profile Slot in the Screw on the bottom left ha...

Page 24: ...to the two top front recesses and rest it on the bottom Slot the left hand side panel into the two top front recesses and rest it on the bottom INSTALLER Screw it on the structure on the left hand sid...

Page 25: ...right hand front profile Slot the top Screw on the top right hand side panel the external right hand profile and the right hand front profile Slot the top right hand side panel Screw on the central s...

Page 26: ...TALLER Insert the assembled right hand side panel Insert the assembled right hand side panel Fasten it to the top and right hand sides with a screw Fasten it to the top and right hand sides with a scr...

Page 27: ...t into the two pins to the right and left and fastening it with the 4 screws on Place the aesthetic top edge by slotting it into the two pins to the right and left and fastening it with the 4 screws o...

Page 28: ...appearing on the following pages appearing on the following pages 1 Right and left refer to the product when viewed from the front Right and left refer to the product when viewed from the front 2 3 4...

Page 29: ...wards the FRONT This can be done by loosening the four fastening screws and turning it Insert the bottom front panel and screw it on Insert the bottom front panel and screw it on hot air outlet hot ai...

Page 30: ...NI 5588 h 4 3 VitecontestaesagonaleISO4017 M5x12 4 3 3 3 3 4 Fitting the steel top front panel 4 Insert the top front panel and screw it on Insert the top front panel and screw it on CERAMIC CLADDING...

Page 31: ...screws on the top then with three screws on the side Repeat the operation for the other side panel Fasten it with two screws on the top then with three screws on the side Repeat the operation for the...

Page 32: ...intervening on the grub screws inserted near the upper slots Adjust the height of the side panel by tightening loosening the grub screws with the Allen key provided the height of the side panel by tig...

Page 33: ...Place the aesthetic top edge by slotting it into the two pins to the right and left and fastening it with the screws on the Place the aesthetic top edge by slotting it into the two pins to the right...

Page 34: ...3 4 cm humidity 10 humidity 10 For reasons relating to safety and environmental For reasons relating to safety and environmental protection DO NOT burn plastic painted wood coal protection DO NOT burn...

Page 35: ...ons there may be a slight smell of paint which will disappear within a short time The product can only be started up once the claddings have been mounted Connect the product to the electricity supply...

Page 36: ...unctions situated on the top see next page APP The Mind can be used for all functions at home with direct connection or away from home through an Internet connection and registration downloadable from...

Page 37: ...ate it again BUTTONS The display has 8 buttons ON OFF toswitchfromtheOFFmodetotheONmode Inthemenus itcanbeusedtoconfirmandreturntothemainscreen to increase decrease the set values or scroll between th...

Page 38: ...s represented by the flame symbols the fan speed which is represented by the filled blades symbol if absent the fan is off The product is programmed by default with a delta of 1 C to optimise comfort...

Page 39: ...tomatically to maintain the set temperature USER M T 14 9 C 15 36 22 0 M T 14 9 C 15 36 22 0 MENU USER INSTRUCTIONS Pressing the button allows for accessing the menu page From the display you can Swit...

Page 40: ...urned OFF or ON If the backlight is switched off it can be activated by pressing any button Pressing the or button will make SET flash and instead of the room set point the number of the fan being mod...

Page 41: ...ts ALARM STATUS In case of shutdown due to alarm the display shows the type of alarm See the paragraph Troubleshooting ON OFF STATUS Stand by activated The product is momentarily off because there are...

Page 42: ...the item with the following button The menu items can appear in different way according the model STAND BY PELLET LOADING TIMER T1 T2 DATE TIME LANGUAGE THe other one are only fort technician The set...

Page 43: ...ng button After entering the Stand by function the display will show the name of the function on the first line of the status bar and the current value on the second line OFF if deactivated ON if acti...

Page 44: ...s used to confirm Pressing the button automatically takes you to the first level PELLET LOADING Allows for loading the pellets once the screw feeder has emptied completely Useful for the technician du...

Page 45: ...from the main menu as indicated in the Menu section above press the button You can scroll the menu items with the and buttons and enter the item with the following button M T 14 9 C 15 36 03 TIMER BA...

Page 46: ...modify the temperature levels OFF T1 and T2 Use the and buttons to scroll the time with 1 2 hour steps M T 15 36 OK SAVE BUTTON off 14 9 C 00 00 M T 15 36 OK SAVE BUTTON off 14 9 C 00 30 day of the w...

Page 47: ...west temperature T2 the highest Modify the values with the and buttons and confirm with the button To access the function from the main menu as indicated in the Menu paragraph above press the button Y...

Page 48: ...s the button You can scroll the menu items with the and buttons and enter the item with the following button After entering the Date Time function the display will show the name of the function on the...

Page 49: ...on the second line Modify the language using the and buttons and exit with the button Pressing the button automatically takes you to the first level To access the function from the main menu as indica...

Page 50: ...readings should only be done when requested by the technician DATA These readings should only be done when requested by the technician Information of the product s HOURS operation log can be scrolled...

Page 51: ...Failure to service the product properly will prevent it from working properly Any problems due to failure in servicing the stove will void the warranty Using the stove without cleaning the grate can...

Page 52: ...C into a non flammable container the ashes may still contain embers and or hot parts or vacuum if cold Vacuum out the interior of the combustion chamber the bed and the compartment around the grate i...

Page 53: ...CE WEEKLY MAINTENANCE When the product is off and cold after having activated the cleaning brush as in routine maintenance you should vacuum the inspection plate under the combustion chamber To do so...

Page 54: ...ti oxidant tablets SPARE PARTS If any spare parts are required contact your dealer or technician Have any repairs carried out only by Edilkamin technical assistance centres authorised dealers The name...

Page 55: ...hat there are pellets in the tank Check that the water temperature has not increased due to the closure of a valve call a technician Contact the technician A04 displays when ignition times out unsucce...

Page 56: ...erature probe failure Contact the technician A13 Shutdown due to breakage of the reading water temperature probe of the boiler stove Contact the technician A14 Shutdown due to breakage of the water te...

Page 57: ...enance should be performed by a qualified technician in accordance with the national and local regulations WATER OVERHEATING SHUTDOWN WITHOUT ALARM If the water in the product reaches a temperature of...

Page 58: ..._____________________________________________ _ _____________________________________________________ _ _____________________________________________________ _ ________________________________________...

Page 59: ..._____________________________________________ _ _____________________________________________________ _ _____________________________________________________ _ ________________________________________...

Page 60: ...cod 942414 GB 02 22 A w w w e d i l k a m i n c o m 942414 GB The names of Edilkamin official authorised technical assistance centres TAC and distributors are available ONLY a www edilkamin com...

Reviews: