background image

19

Electric cable connections (fig. N)

In order to connect the electrical cables
to the control unit inside the mecha-
nism(4) you must proceed as follows:
- remove the 4 screws from the front

panel (4a)

- connect the cables to their sites by

inserting their connectors, which must
be inserted without forcing them

- connect the plug to the mains and

check that the synoptic panel is 
functioning properly by following 
the instructions attached to it

- reassemble the front panel being 

careful not to bend or crush the 
synoptic panel cable, then proceed with

the installation of the fireplace.

- these procedures must meet installation

standards and be built to the highest
professional standards.

14

22a

22

6a

13

12

12

13

14

rete 230 Vac

• the first side panel
• front Panel
- secure outlets (22) in the top part of

the frames after making a hole of 
37x10, 5 cm

- secure the sensor (14) inside the hole

(22a) of the outlet (B1 or B3)

- check that the wire of the sensor does

not interfere with the movement of 

the retractable door

• the second side panel
- finish the mantel by mounting the

second side panel

- and apply the snap on grilles to the

outlets from the outside

- when the work is complete, plug in 

the plug to the 230 Vac power supply

- ensure that the electrical wires do not 

have any areas of contact with the 
prefabricated appliance and the smoke 

channel 

- no parts of the electrical equipment 

supplied with the fireplace must be 
tampered with

- the electrical components are always

live, prior to any work, unplug the 
equipment or turn off the general 
electrical panel for the housing.

Connecting forced ventilation 
(fig. N-O)

- extend the lead with the plug all the 

way to the socket

- mount the covering all the way up to

the beam, and then build the mantel
with plasterboard panels as follows:

INSTALLATION INSTRUCTIONS

fig. N

fig. O

ENGLISH

unit

outlet

sensor

230 Vac
power supply

fan

electrical control 

Summary of Contents for 809490

Page 1: ...TITANO UP2 UK Installation use and maintenance ...

Page 2: ...all relieve the manufacturer from any damage resulting from the use of this product the proof of purchase tag necessary for identifying the fireplace is located on the top of the package in the warranty booklet found inside the firebox on the ID plate affixed to the back side of the unit This documentation must be saved for identification together with the valid proof of purchase receipt The data ...

Page 3: ...ure MANIGLIA ASPORTABILE PER APERTURA PORTELLONE The handle of the hatch is not fixed to the same hatch but is inserted when required The handle fits into the bottom of the door by hooking it onto the pins The handle is only needed to lift or lower the hatch BUILT IN SYNOPTIC PANEL for models with forced ventilation it allows you to manage and control the operating phases ignition and turning off ...

Page 4: ... controlled mechanism recessed in the bottom front panel of the firebox When the fireplace is operating control lever 1b must be par tially or fully positioned to the right room outside air fitting 4b the sensor cables and the 230 Vac power supply can be positioned independently either to the left or to the right hot air outlet SPECIFICATIONS 4b 4b 1b A C hot air outlet pipes 230 Vac power supply ...

Page 5: ...type of surfaces present and how they are made Hot air outlets Grillsr The hot air outlets must be placed at a minimum distance of 50 cm from the ceiling and 30 cm from the furniture Position the grills or the air outlets at the highest point of the covering in order to avoid heat accumulating insi de the same covering Position the grills or the air outlets so that they can be easily accessed for ...

Page 6: ...place mantels and their vents fig 1 Before installing the covering make sure that the connections control levers and all moving parts are functioning correc tly These checks must be performed when the fireplace is lit and has been running for a few hours before covering the firebox so that it is still possible to intervene if necessary Therefore the fini shing operations such as building the firep...

Page 7: ...hem with their clamps build the frame with the fitting for outlet B1 into the wall on the top part of the fireplace mantel build the frame with the fitting for outlet B3 into the wall of the room requiring heating connect the two aluminium pipes to the fittings and secure them with clamps and snap on the front grilles Kit Three bis for the room where the fireplace is installed plus two adjacent ro...

Page 8: ...orting the fireplace In order to facilitate transportation the fireplace can be made lighter by remo ving the following counter weights cast iron bottom cast iron sides cast iron hearth the ash pan the ash grill made of cast iron the outer shell Dismantling the door Phase 1 fig H I lower the door to the fully closed position move levers X and X1 towards their respective jambs Phase 2 fig L open th...

Page 9: ...5 cm secure the sensor 14 inside the hole 22a of the outlet B1 or B3 check that the wire of the sensor does not interfere with the movement of the retractable door the second side panel finish the mantel by mounting the second side panel and apply the snap on grilles to the outlets from the outside when the work is complete plug in the plug to the 230 Vac power supply ensure that the electrical wi...

Page 10: ...stalled on the mantel of the covering When the fan is off the fireplace runs on natural convection Operating on forced ventilation in Automatic The fan is connected to a sensor moun ted on the hot air outlet on the mantel which starts up automatically once it reaches a temperature of 40 C and stops again automatically when the temperatu re drops below 40 C Manual The fan begins operating regardles...

Page 11: ...liquid fuel such as petrol alcohol or similar Do not burn waste Radiation field Do not place any fuel object inside the radia tion field of the glass hatch Initial start up The paint of the hearth is subject to the so cal led ageing until the working temperature is reached for the first time This may cause unpleasant odours In such case adequately air the room where the hearth is installed The phe...

Page 12: ...rafusado é o painel de fundo 2a as partes laterais 2b 2c devem ser simple smente colocadas em posição atenção permanecem instáveis até a montagem do painel de fundo 2a parte lateral anterior esquerda 2c parte lateral posterior esquerda 2b parte lateral posterior direita 2b painel de fundo com guarnição 2a desparafusar os dois parafusos inseridos na parte inferior da estrutura realizada com chapas ...

Page 13: ...n 2 viti 2 screws 2 tornillos 2 parafusos 2 βίδες 2 винта sk tecnica multi MONTAGGIO GHISE TITANO PLUS Layout 1 24 05 2012 16 59 Pagina 2 ...

Page 14: ...rafusado é o painel de fundo 2a as partes laterais 2b 2c devem ser simple smente colocadas em posição atenção permanecem instáveis até a montagem do painel de fundo 2a parte lateral anterior direita 2c parte lateral posterior direita 2b parte lateral posterior esquerda 2b painel de fundo com guarnição 2a desparafusar os dois parafusos inseridos na parte inferior da estrutura realizada com chapas m...

Page 15: ...n 2 viti 2 screws 2 tornillos 2 parafusos 2 βίδες 2 винта sk tecnica multi MONTAGGIO GHISE TITANO PLUS Layout 1 24 05 2012 16 59 Pagina 4 ...

Page 16: ...942074 GB 04 19 A w w w e d i l k a m i n c o m ...

Reviews: