background image

18

fig. E

External air inlet (figures E-F-G)
It is absolutely necessary, without
exception, to build a connection to the
outside with a cross-section of 300 cm²
for the proper functioning of the fire-
place.

This connection must link the adju-
stment mechanism outlet located on the
side of the mechanism itself with the
outside.
This can be achieved with a flexible alu-
minium pipe and properly sealing the
points where air leakage could occur.

The Ø20 aluminium pipe can be posi-
tioned independently either to the
right or to the left of the adjustment
mechanism.

It is advisable to place a protection gril-
le on the outer part of the air inlet chan-
nel, nevertheless  ensuring that this does
not reduce the cross-section.

The inflow of outside air must be at floor
level (it can not come  from above).
.

When positioning the outdoor air
damper control cable (4c), make sure
that it does not come into contact with
the hot parts of the fireplace, as this
will damage the plastic sheath.

INSTALLATION INSTRUCTIONS

fig. F

fig. G

ENGLISH

Transporting the fireplace

In order to facilitate transportation, the
fireplace can be made lighter by remo-
ving the following:
- counter weights, cast iron bottom, cast
iron sides, cast iron hearth, the ash pan, the
ash grill made of cast iron, the outer shell.

Dismantling the door

Phase 1  (fig. H-I)

- lower the door to the fully closed

position

- move levers X and X1 towards their

respective jambs. 

Phase 2  (fig. L)

- open the door
-  loosen safety grub screw  Y
-  reclose the door
-  put levers X and X1 back into their

original positions 

Phase 3  (fig. L) 

-  lift the door up approximately 10 cm

in order to fully unscrew the Allen 

screw (Z).                

- lower the door until it is in the fully 

closed position

- Take care that the door does not come

out of its housing. 

- move levers X and X1 towards their 

respective jambs again; open the door. 

-  pull (very carefully) the lower part of

the door towards you, in order to 
remove it from its housing. 

Cleaning the glass (fig. M)

Note: before proceeding, move the 

two levers, X and X1, towards their
respective jambs.

- open the door and using the appro

priate tool (cold handle supplied) 
release the latch plate on the jamb of 
the short side of the door (rotate 90°).

- relcose after cleaning, fastening the 

latch plate. 

X

X1

fig. L

fig. I

Z

Y

fig. M

fig. H

Summary of Contents for 809490

Page 1: ...TITANO UP2 UK Installation use and maintenance ...

Page 2: ...all relieve the manufacturer from any damage resulting from the use of this product the proof of purchase tag necessary for identifying the fireplace is located on the top of the package in the warranty booklet found inside the firebox on the ID plate affixed to the back side of the unit This documentation must be saved for identification together with the valid proof of purchase receipt The data ...

Page 3: ...ure MANIGLIA ASPORTABILE PER APERTURA PORTELLONE The handle of the hatch is not fixed to the same hatch but is inserted when required The handle fits into the bottom of the door by hooking it onto the pins The handle is only needed to lift or lower the hatch BUILT IN SYNOPTIC PANEL for models with forced ventilation it allows you to manage and control the operating phases ignition and turning off ...

Page 4: ... controlled mechanism recessed in the bottom front panel of the firebox When the fireplace is operating control lever 1b must be par tially or fully positioned to the right room outside air fitting 4b the sensor cables and the 230 Vac power supply can be positioned independently either to the left or to the right hot air outlet SPECIFICATIONS 4b 4b 1b A C hot air outlet pipes 230 Vac power supply ...

Page 5: ...type of surfaces present and how they are made Hot air outlets Grillsr The hot air outlets must be placed at a minimum distance of 50 cm from the ceiling and 30 cm from the furniture Position the grills or the air outlets at the highest point of the covering in order to avoid heat accumulating insi de the same covering Position the grills or the air outlets so that they can be easily accessed for ...

Page 6: ...place mantels and their vents fig 1 Before installing the covering make sure that the connections control levers and all moving parts are functioning correc tly These checks must be performed when the fireplace is lit and has been running for a few hours before covering the firebox so that it is still possible to intervene if necessary Therefore the fini shing operations such as building the firep...

Page 7: ...hem with their clamps build the frame with the fitting for outlet B1 into the wall on the top part of the fireplace mantel build the frame with the fitting for outlet B3 into the wall of the room requiring heating connect the two aluminium pipes to the fittings and secure them with clamps and snap on the front grilles Kit Three bis for the room where the fireplace is installed plus two adjacent ro...

Page 8: ...orting the fireplace In order to facilitate transportation the fireplace can be made lighter by remo ving the following counter weights cast iron bottom cast iron sides cast iron hearth the ash pan the ash grill made of cast iron the outer shell Dismantling the door Phase 1 fig H I lower the door to the fully closed position move levers X and X1 towards their respective jambs Phase 2 fig L open th...

Page 9: ...5 cm secure the sensor 14 inside the hole 22a of the outlet B1 or B3 check that the wire of the sensor does not interfere with the movement of the retractable door the second side panel finish the mantel by mounting the second side panel and apply the snap on grilles to the outlets from the outside when the work is complete plug in the plug to the 230 Vac power supply ensure that the electrical wi...

Page 10: ...stalled on the mantel of the covering When the fan is off the fireplace runs on natural convection Operating on forced ventilation in Automatic The fan is connected to a sensor moun ted on the hot air outlet on the mantel which starts up automatically once it reaches a temperature of 40 C and stops again automatically when the temperatu re drops below 40 C Manual The fan begins operating regardles...

Page 11: ...liquid fuel such as petrol alcohol or similar Do not burn waste Radiation field Do not place any fuel object inside the radia tion field of the glass hatch Initial start up The paint of the hearth is subject to the so cal led ageing until the working temperature is reached for the first time This may cause unpleasant odours In such case adequately air the room where the hearth is installed The phe...

Page 12: ...rafusado é o painel de fundo 2a as partes laterais 2b 2c devem ser simple smente colocadas em posição atenção permanecem instáveis até a montagem do painel de fundo 2a parte lateral anterior esquerda 2c parte lateral posterior esquerda 2b parte lateral posterior direita 2b painel de fundo com guarnição 2a desparafusar os dois parafusos inseridos na parte inferior da estrutura realizada com chapas ...

Page 13: ...n 2 viti 2 screws 2 tornillos 2 parafusos 2 βίδες 2 винта sk tecnica multi MONTAGGIO GHISE TITANO PLUS Layout 1 24 05 2012 16 59 Pagina 2 ...

Page 14: ...rafusado é o painel de fundo 2a as partes laterais 2b 2c devem ser simple smente colocadas em posição atenção permanecem instáveis até a montagem do painel de fundo 2a parte lateral anterior direita 2c parte lateral posterior direita 2b parte lateral posterior esquerda 2b painel de fundo com guarnição 2a desparafusar os dois parafusos inseridos na parte inferior da estrutura realizada com chapas m...

Page 15: ...n 2 viti 2 screws 2 tornillos 2 parafusos 2 βίδες 2 винта sk tecnica multi MONTAGGIO GHISE TITANO PLUS Layout 1 24 05 2012 16 59 Pagina 4 ...

Page 16: ...942074 GB 04 19 A w w w e d i l k a m i n c o m ...