21
ENGLISH
FRONTAL VENTILATION KIT
CONTENTS
• Pre-assembled frontal ventilation kit (2)
• snap fitted grille and ceramic assembly (3)
• top front panel of frontal closure
ASSEMBLY INSTRUCTIONS
1. unscrew the metal cover on the top part of the frame (1)
2. replace the metal cover (1) which will no longer be used with the pre-assembled Kit (2), and screw it on to the
sides
3. electrically connect the fan to the circuit board as shown on the high-voltage terminal board to the side (poles
7,8,9, Line, Earth, Neutral respectively)
4. position the snap fitted grille and ceramic assembly (3) and secure it frontally with the self-tapping screw provided
5. position the top front panel of the frontal closure (4) and screw it on with one screw per side
6. the fan must then be activated by an Edilkamin Assistance Centre, using the reserved settings menu.
1
2
3
4
VERSION WITH FRONTAL VENTILATION AND TRAPDOOR LOADING (2)