ELECTRICAL AND AUXILIARY HOOKUP
The appliance is equipped with an electrical power
cord for connection to a 230V 50 Hz socket, preferably
with a trip switch.
Variations in voltage of more than 10% can compromise
its operation.
The electrical system must be compliant; check
the operation of the earth in particular. Edilkamin is
not responsible for malfunctions resulting from an
improperly grounded system. The power line must be
of adequate section for the power of the appliance.
The power cable must not come into contact with the
flue or other hot parts of the product.
INSTALLATION
1
2
3
4
5
6
7
8
9
10
11
12
fan 3 connection (phase,
ground, neutral)
fan 2 connection (phase,
ground, neutral)
for optional frontal fan kit
Pre-wired electrical power
connection
TERMINAL BOARDS
The right side of the appliance (seen from the front)
has a bracket with two terminal boards:
• the upper terminal board (low voltage) has a pre-
wired cable for the reset button, while the rest is for
use by Edilkamin technicians only
• the lower terminal board (high voltage) is for the
electrical power and fan connections;
1
2
3
4
5
6
7
8
9
10
11
12
free
clean contact
(AUX)
reset button
already wired
for Edilkamin technicians only
these connections may be made by a
qualified electrician only.
all work must be done with electrical
power switched off
upper terminal board (low voltage)
lower terminal board (high voltage) VERSIONS WITH DUCTED VENTILATION (versions 1 and 4)
upper terminal board (low voltage)
lower terminal board (high voltage)
1
2
3
4
5
6
7
8
9
10
11
12
NOT USED
NOT USED
for front fan kit (Line 7,
earth 8, neutral 9)
Pre-wired electrical power
connection
lower terminal board (high voltage) VERSIONS WITH FRONTAL VENTILATION (versions 2 and 3)