EASY ROOF FLAT SYSTEM assembly instructions
3
In addition, in accordance with the provisions of §9.1 of DTU43.1 (Roofs receiving permanent heavy
equipment, regardless of the destination), the connections between equipment and the terraced roof
must allow servicing and overhaul of sealing structures.
The EASY ROOF FLAT process is designed for easy removal (and/or) transport without the need for
lifting machinery (the ballast must never be more than 67 kg).
Every component (KITS with reference bases
092406
) will rest on an appropriate resilient material
(expanded or extruded polystyrene) or on the footing provided by EDILIANS.
These spread components (intended to prevent any pinching of the damp proof course) will be sized as
follows:
The smallest support dimension is no less than
0.40 m
.
The pressure at the sealing coating is limited in the conditions below.
The maximum pressure under every slab must be calculated by the company in charge of equipment
implementation (in accordance with §3.1 ag) of FD P 84-204-3].
The project manager verifies the compatibility between the calculated pressures resulting from the
equipment and the allowable pressures (in accordance with FD P 84-204-3).
For a coating under reversed insulation
, the allowable pressure is the
smaller of the following two
values
:
The one indicated in the table below,
The one indicated in the Technical Application Document for the insulating panel.
For a sealing coating on insulating panel support
, the allowable pressure is the
smaller of the
following three values:
- The one indicated in the table below (caution: remember (see §6.5.1 of DTU43.1) that Class I2
SBS elastomer bilayer coatings are not permitted on insulating panel supports).
- The one indicated for this use in the
application documents for sealing support insulating
panels
other than cork-based supports,
- 4 kPa (0.04 daN/cm
2
) for sealing coatings applied to insulating panels in expanded
agglomerated cork.
Table (DTU43.1 extract): Allowable pressure on masonry support coating