EASY ROOF FLAT SYSTEM assembly instructions
2
FITTING INSTRUCTIONS
Before installing the EASY ROOF FLAT base, spread footings must be available as stipulated in DTU43.1
SAFETY INSTRUCTIONS
The planning, fitting and commissioning of the installation must only be carried out by qualified
personnel. Incorrect execution can result in damage to the system and can put lives in danger.
It is imperative to comply with national and local construction standards, miscellaneous regulations and
environmental protection directives in force*.
Safety regulations and accident prevention instructions must be observed. Appropriate fall prevention
devices must be used for all work performed at height.
Before assembly, it is your responsibility to check the amount of ballast, the load capacity of the roof
and the compatibility of the installation with the various roof coatings/insulations.
Before assembly, check that you have the up-to-date version of the assembly instructions on our
website: http://fr.edilians.co.uk/supports/. Throughout the installation operation, make sure that at
least one copy of the installation instruction manual is available on site.
Please take into account the module
manufacturer’s
assembly instructions.
To remove the system, apply the installation procedure in reverse.
Compliance with the safety and operating instructions for the system entitles you to a ten-year product
warranty**.
ASSEMBLY ADVICE
This system can be installed on all flat horizontal surfaces, mainly common terrace roofs with a bearing
structure of sufficient load capacity and a roof slope of up to 5%.
The distributed surface load of the installation with its ballast must be no more than the residual load
capacity of the building. As a rule, all the technical aspects of the support, roof and building must be
checked before assembly. When in doubt, a building professional must be consulted.
The process can only be implemented on roofing with a technical opinion or a technical application
document that allows the installation of technical components, in accordance with DTU43.1 or DTU43.11.
In particular, the insulation on the underside of the damp proof course must be at least
Class C
in
accordance with the CSTB Technical Guide UEAtc (1) for the approval of sealing support insulating
systems for flat and sloping roofs (
Specification 2662_V2 - July 2010).
* Compliance with NF C15-712 is especially important in France.
** EDILIANS fitter training information.