background image

T3D User  Manual

030705

T3D User’

s Manual

Front panel controls and connectors

Power: 

Turns the T3D on.

Function:  

Selects various modes of operation when
held down.  Also used to initiate calibration
sequence.

Sensitivity -:

Reduces the sensitivity to the transducer’

resonant points.  Also used with Function
button to turn unit off.

Sensi: Increases the sensitivity to the transducer’

resonant points.  Additionally used to
display temperature in degrees Fahrenheit
when in the temperature test mode.

Multi-function:

Used to test transducers with combined
depth-temperature-speed functions.

Standard: 

Use to connect to piezoelectric transducers
in the 50 to 500 kHz range.

Quick start

Connect the T3D to a piezoelectric transducer and turn it on by pressing the 

power

 button. The

bar graph will show one or more illuminated sections corresponding to the resonant points of the
transducer.  If no lights come on, the transducer element is bad.  The T3D will turn off after two
minutes of operation.  It can also be turned off by pressing both the 

function

 and  

-sensitivity

buttons.

Other tests

Multifunction transducers may be tested for correct operation of the thermistor and the speed
paddle wheel by connecting them to the 8-pin 

multi-function

 connector.  The 8-pin connector

wiring is configured for the most popular multi-function transducers and is detailed at the end of
this manual.

Leakage

The leakage test is activated by holding the 

function 

button down until the segment next to 

leak

flashes.  An open circuit (> 10 meg ohms) will cause all segments to light.  A short (<10 ohms)
will light only the segment next to

 0

.

Temperature

Again press and hold the 

function

 button until the segment next to 

temp

 blinks.   The first digit of

the temperature is indicated by the flashing segment and the second digit by a steady segment. 
The readout is in degrees centigrade unless the 

E

F

 button is held down for a Fahrenheit reading.

Speed

Reviews: