CMU-24VDC-ITL Cabinet Monitor Unit
Operations Manual
Eberle Design Inc.
Page 17
Multiple
Fault ........................................................................................... greater than 450 ms
No Fault ........................................................................................... less than 200 ms
Typical ............................................................................................................ 350 ms
Lack of Signal Inputs
Fault ......................................................................................... greater than 1000 ms
No Fault ........................................................................................... less than 700 ms
Typical ............................................................................................................ 850 ms
Yellow Clearance
Fault .............................................................................................. less than 2600 ms
No Fault .................................................................................... greater than 2800 ms
Typical .......................................................................................................... 2700 ms
Yellow Plus Red Clearance
Fault .............................................................................................. less than 2600 ms
No Fault .................................................................................... greater than 2800 ms
Typical .......................................................................................................... 2700 ms
Field Check
Fault ......................................................................................... greater than 1000 ms
No Fault ........................................................................................... less than 700 ms
Typical ............................................................................................................ 850 ms
Local Flash Status, Circuit Breaker Trip
Fault ........................................................................................... greater than 450 ms
No Fault ........................................................................................... less than 200 ms
Typical ............................................................................................................ 350 ms
DC Power Fail Monitor
Fault ........................................................................................... greater than 225 ms
No Fault ........................................................................................... less than 175 ms
Typical ............................................................................................................ 200 ms
NRESET, POWERDOWN
Active .......................................................................................... greater than 120 ms
Not Active .......................................................................................... less than 80 ms
Typical ............................................................................................................ 100 ms
5.3 MECHANICAL
Height ............................................................................................................... 4.166 inches
Width ................................................................................................................ 2.340 inches
Depth (front panel to rear edge of DIN connector) ............................................ 7.682 inches
5.4 ENVIRONMENTAL
Storage Temperature Range ........................................................................... -45 to +85
o
C
Operating Temperature Range ........................................................................ -34 to +74
o
C
Humidity (non-condensing) ....................................................................... 0 to 95% Relative