background image

 

 

 

Warning: Use two or more people to move and install the outdoor beverage refrigerator. 

Failure to do so can result in back or other injury. Carefully remove the packaging materials. 

Remove any shipping tape and glue from your outdoor beverage refrigerator before use. Do 

not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove 

tape or glue. These products can damage the surface of your outdoor beverage refrigerator.  
 

 

 

Important: Do not remove any safety, warning, or product information labels from your outdoor 

beverage refrigerator.  
 

 

Internal Fan 

 

This unit is equipped with an internal fan that maintains a consistent internal temperature. 
 

Installing the Outdoor Beverage Refrigerator 

The outdoor beverage refrigerator should be installed in accordance with local electrical code 

requirements. The refrigerator should also be placed in a location that is strong enough to 

support its total weight, keeping in mind that it will weigh substantially more when fully loaded 

than when empty. 

Before you plug the beverage refrigerator into a power supply, be sure 

to let it stand upright for at least 24 hours to allow the compressor’s oils to settle.

  

 

Unpacking the Outdoor Beverage Refrigerator 

 
 
 
 
 
 
 
 
 
 
 
 

Types of Installation 

This outdoor beverage refrigerator has been designed for freestanding or built-in installation. In 
each case, there must be adequate ventilation and access for service.  

Freestanding Installation: 

A freestanding installation will allow you to install the outdoor beverage refrigerator in almost 
any place you desire. You must follow the stated instructions for electrical requirements, and 
leveling the outdoor beverage refrigerator. 

Built-in Installation: 

A recessed installation will allow you to install the beverage cooler under a counter or in a 
kitchen cabinet provided the required clearance space around the beverage cooler is 
fulfilled. It is necessary to allow adequate ventilation space around the unit, including the 
back. The following additional items must be observed: 
1. 

Place the outdoor beverage refrigerator in front of the installation location. Adjust the 
feet and place the unit flat on the floor or on a platform depending on your installation 
requirements. 

2. 

If the electrical outlet for the outdoor beverage refrigerator is behind the cabinet, plug 
in the outdoor beverage refrigerator. 

3. 

Push the outdoor beverage refrigerator into position.  

 
 
 
 
 

 
Warning: Do NOT install the outdoor beverage refrigerator behind a closed cabinet door. 

Summary of Contents for OBR901SS

Page 1: ...door Beverage Refrigerator Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com To use the EdgeStar self diagnostic tool go to https support edge...

Page 2: ...es is required Use outlets that cannot be turned off by a switch or pull chain Unplug the unit if you are going to clean it or when it is not going to be used for an extended period of time Do not ope...

Page 3: ...to the cooler before they cool down to room temperature In a rainy environment a water proof covering is recommended This unit is not intended to be used by children Children should be supervised to e...

Page 4: ...REQUIREMENTS 7 ELECTRICAL REQUIREMENTS 8 Recommended Grounding Method 8 LEVELING THE OUTDOOR BEVERAGE REFRIGERATOR 8 INSTALLATION CHECK LIST BEFORE OPERATION 9 OPERATION 10 CONTROL PANEL OVERVIEW 10...

Page 5: ...oduct packaging in case you need to safely transport your outdoor beverage refrigerator For Your Records Please write down the model number and serial number below for future reference Both numbers ar...

Page 6: ...5 Tip Gather the model and serial number from the product label and write them down before installing the outdoor beverage refrigerator Parts Identification Back View Front View...

Page 7: ...the compressor s oils to settle Unpacking the Outdoor Beverage Refrigerator Types of Installation This outdoor beverage refrigerator has been designed for freestanding or built in installation In eac...

Page 8: ...service access and ventilation allow at least 1 2 clearance at the back 1 at the top and 1 2 at the sides The installation should allow the unit to be pulled forward for servicing if necessary The ou...

Page 9: ...st be grounded It is equipped with a power supply cord that has a 3 pronged grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 pronged wall socket and grounded i...

Page 10: ...it from the unit 5 Continue to pull the shelf forward until it is completely removed from the inner compartment Installation Check List Before Operation 1 Have all packing materials and tape been rem...

Page 11: ...o turn the interior light on or off Set Temperature This button is used to adjust the temperature Up This button increases the set temperature in 1 degree increments Down This button decreases the set...

Page 12: ...or In the event that there is an error detected an alarm indicator will appear on the screen In the alarm mode the unit will make a beeping sound and display an alarm message LOW TEMP This message ind...

Page 13: ...defrost system in which the refrigerated surfaces of the unit defrost automatically Defrost water drains into a hole in the floor of the storage compartment and is channeled into a drain pan located...

Page 14: ...roughly with a soft cloth To clean the door gasket use only mild soapy water Never use harsh cleansers or scouring pads to clean any part of your unit Interior Cleaning Unplug your beverage refrigerat...

Page 15: ...oned Contact EdgeStar customer service The outdoor beverage cooler does not turn on There is a power failure Ensure the cooler is plugged in and the power outlet has power The cooler is not plugged in...

Page 16: ...sting may be required If frost builds up you can try running the cooler on a warmer temperature setting minimizing the number of times you open the doors or unplugging the unit to allow the frost to m...

Page 17: ...Capacity 84 Cans Refrigerant R134a 2 3 oz High Low Side Pressure 190 90 psig Compartment Temperature Range 38 F 65 F Operating Temperature Range 40 F 100 F Dimensions Height x Width x Depth 33 5 16 x...

Page 18: ...al use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 12 month period Products that have been modified to perform outside of sp...