6
LED Display
There are 2 LED displays located on the control panel of this unit.
Temperature and Timer Display
When operating normally, this will display the current temperature in the room where the
dehumidifier is located. When adjusting the timer setting, this will display the hours
remaining for the timer.
Humidity Level Display
When operating normally, this will display the current relative humidity in the room where the
dehumidifier is located. When adjusting the desired humidity setting, this will display the
humidity level you set.
Error Codes
In addition to showing the humidity, the display screens may show the following error codes:
E1 -Temperature sensor error
E2 - Defrost sensor error
E3- Humidity sensor error
For El, E2, and E3 error codes, power the unit off, and then unplug the unit for 15 minutes.
Plug the unit in and power i t on. If the issue persists, please contact customer service.
LO- Temperature too low error
This means the current room temperature is below 32°F. Make sure the ambient
temperature is suitable for the unit (41°F- 95°F). If the ambient temperature is suitable,
please contact customer service.
HI- Temperature too high error
This means the current room temperature is above 122°F. Make sure the ambient
temperature is suitable for the unit (41°F- 95°F). If the ambient temperature is suitable,
please contact customer service.
Water Full Light
The Water Full Light will illuminate when the bucket is ready to be emptied. The light also turns
on when the bucket is not installed at all or is not installed correctly. Once the water is drained,
and the bucket is properly installed, the light will no longer illuminate and the unit will operate
normally.
Additional Notes About the Dehumidifier’s Behavior
•
Once the unit reaches the desired humidity level, the power button will remain lit while the
compressor and fan shut off.
•
When turning the unit off and back on in a normal manner the dehumidifier will retain its
last target humidity settings except In the event of a power interruption (i.e. power
outage or if unit is unplugged).
•
If the unit is turned on when the room's relative humidity is lower than the desired humidity
level, the unit will run for a short period of time and then the compressor and fan will shut
off.