13

 

 

 

verifying no bad connections replace the fan unit . 

2. How to check the PTC heater 

Check the resistance of PTC heater using a 

Multimeter

; the reading should be approx 1.5 K

Ω

 (assuming normal 

temperature), if open circuits Replace the PTC heater having once verified the connections to the PTC 
heater.Replace new one. 

3. If no fault in the fan or PTC heater, replace the main PCB, 

 

8.3 NOISE OF WINE COOLER 
 

 

COMPRESSOR NOISE 

    

1. The working of motor and piston motion will cause noise when compressor working. So if noise is steady and not 

exceeds 42 dB, it’s normal. If noise is not steady or very high, it’s compressor fault and it should be repaired or 
replaced. 

2. If compressor’s shock absorption rubber is hardening or damaged, or fixing screw of compressor is too tight or 

loose, it will cause noise. The settlement is to change new shock absorption rubber or adjust fixing screws. 

 

 

FAN NOISE 

1. When the fans are running , the vanes are circumrotating rapidly and the air flows, which will cause steady and 

standard noise. The noise should not exceed 32dB and it is normal. 

2. If the noise is extremely high and abnormal, the cause maybe as below  

a. The axis of the fan is broken 
b. The fan is broken and lost balance 

 

 

REFRIGERANT JET NOISE 

            COMPLAINT

: If here is intermittent noise like a water spray from the capillary. 

CAUSE

: The end of the capillary in the evaporator is in the wrong position, or there are rough edges on the end of 

the capillary 

REMEDY

:        

1>. Heat the soldered joint of the capillary (“A” of Fig.8), then remove the capillary from the evaporator and smooth 

the end with an eraser. (Caution: do not allow any particles into capillary unit) 

2>. Replace the capillary into the evaporator, then solder it back into the correct position (not exceeding 15mm in 

the evaporator) and pack the joint with anti vibration compound 

3>. Recharge with refrigerant. 

 

 

CAPILLARY VIBRATION NOISE 
COMPLAINT

: high frequency impact noise in capillary Zone. 

CAUSE

       1>. The capillary being insert too deep into the evaporator, so when the refrigerant is Jetting, the end of vibrating 

capillary will hit the inside of the evaporator. 

2>. Vibration from the capillary touching the inside of the cabinet or air duct board, then when refrigerant is jetting.  

REMEDY

1>. If the capillary is inserted too deep, heat it with the solder, solder it again(Please noted, the deep inserted is 

not bigger than 15mm), and vacuumize it and add the refrigerant.  

2>. If the capillary touch the inner cabinet and the air duct panel, adjust the position of the capillary and add the 

incabloc plastic. 

 

 

OIL JAMMED NOISE 
COMPLAINT

: intermittent and deep jet noise coming from inside of the capillary. 

CAUSE

: Compressor oil flowing into the cooling system pipe work because of wine cooler lean during 

transportation, and the jetting oil in the capillary cause noise.  

REMEDY

:Clean the cooling system pipe, and recharge with refrigerant 

 

8.4 EVAPORATOR FREEZING 

CAUSE

:The gasket is not air-proof, or the door is not closed well, cause much water fill in the the cabinet, and the 

water got frozen when it encounter the cold air, sometimes the ice is too thick, and it will block the fan or 
broken the fan. 

Summary of Contents for CWR460DZ

Page 1: ...1 WINE CELLAR SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL DUAL ZONE MODEL CWR460DZ...

Page 2: ...ER PCB 14 TROUBLESHOOTING 15 TROUBLES SHOOTING GUIDE 15 SAFETY PRECAUTIONS Please read the followings before servicing your wine storage 1 Check if an electric leakage occurs in the set 2 To prevent e...

Page 3: ...DDLE PARTITION 5 LARGE SHELVES 6 SECURITY LOCK 7 BOTTOM SHELF 8 BOTTOM GRILLE 9 LEVELING LEGS 10 CABINET 2 REFRIGERANT CYCLE DIAGRAM 1 Compressor 2 Hot Pipe 3 Condenser Internal 4 Condenser Fan 5 Cond...

Page 4: ...reverse the opening direction please follow these instructions Note All parts removed must be saved to do the reinstatement of door 1 Open the glass door and remove the two screws under the right bot...

Page 5: ...way the door gasket a around the area where the handle is to be installed AS INDICATED IN ILLUSTRATION 1 NOTE The gasket is easily displaced by hand no tools are necessary 2 Using a type head screwdri...

Page 6: ...to remove all items first Then move the shelf to the position where the notch of shelf is exactly under the plastic post and lift the shelf In order to replace the shelf repeat steps described above i...

Page 7: ...is located in the following position 9 Press the plastic nail supporting the control PCB with forefinger and thumb pull the control PCB upward take away it then you can replace the new control PCB 10...

Page 8: ...g to How to remove the shelves 2 The lower zone sensor and PTC heater fan motor are located in the following position 3 Remove the two screws that are used to connect the top plate of middle partition...

Page 9: ...dle partition with the rear air duct cover 10 Remove one screw that are used to fix the light cover with the bottom plate of middle partition 11 Disconnect the housing from the LED light assembly In t...

Page 10: ...lower zone sensor please follow these instructions A Disconnect all the wires the pull out the rear air duct cover Press the nails fixing the senser cover use screwdriver at the back of the rear air...

Page 11: ...are used to fix the junction box with the cabinet 3 Disconnect the condenser fan motor cables on the power PCB then you can replace the condenser fan motor 4 Remove the clamp that is used to fix the j...

Page 12: ...NG THE EVAPORATOR PTC HEATER CONTROL PCB FAN MOTORS SENSORS B Make sure the cooling system of the soldering point is normally Then cut off the capilary around the dry filter and infuse 0 8 1MP nitroge...

Page 13: ...ed joint of the capillary A of Fig 8 then remove the capillary from the evaporator and smooth the end with an eraser Caution do not allow any particles into capillary unit 2 Replace the capillary into...

Page 14: ...again until it fix for the door 2 If the fan is Jamed seriously or breacken replace it with the new fan 9 DESCRIPTION OF CONTROL PCB POWER PCB CONTROL PCB 1 To Evaporator Fan Motor Red 2 To Lower Zone...

Page 15: ...s burned out The light button is OFF Vibrations Check to assure that the Wine Chiller is level The Wine Chiller seems to make too much noise The rattling noise may come from the flow of the refrigeran...

Reviews: