EdgeStar AP14002HS Owner'S Manual Download Page 2

i

Important Safety Information

Improper handling can cause serious damage to the appliance and/or to the 
user. Please read the following safety information.  

Your portable air conditioner is supplied with a Leakage-Current 
Detection and Interruption (LCDI) safety plug. This device provides 
protection to reduce the risk of fire due to arcing faults in the power 
supply cord. Before using your portable air conditioner, follow the 
instructions below to ensure that the LCDI plug is working properly:  

1.  Plug the power cord to a grounded outlet. 
2.  Press the TEST button on the LCDI plug. This should trip the 
plug and cut the power to the air conditioner. If the plug does not 
trip and you are able to turn on the unit, please contact EdgeStar 
support. 

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS. 

Press the RESET button to start using your air conditioner.  

Do not use the TEST and RESET buttons as an ON/OFF switch. 

Electrical products should not be disposed of with household waste. 
Please contact your local recycling center for more information on how 
to recycle electronic waste. 

Electrical Safety 

x

 

This unit is designed for indoor use only. 

x

 

Do not use the unit in extremely humid or wet environments. 

x

 

Do not spray water and wet the housing or control panel. 

x

 

Do not pull the unit by the cord. 

x

 

Always turn the unit off and unplug it from the outlet when cleaning. 

x

 

Unplug the unit if it is not going to be used for a long period of time.  

x

 

Do not operate the unit with a damaged plug or a loose socket. 

x

 

Use only the correct power supply with appropriate amperage. 

x

 

If the power cord is damaged, it must be replaced by the manufacturer, 
a service agent, or qualified technician.  

x

 

Do not remove any part of the casing unless instructed by an 
authorized technician. 

General Safety 

x

 

This portable air conditioner is not intended to be used by children. 

x

 

Children should be supervised to ensure that they do not play with this 
product. 

x

 

Do not allow children to play with the controls or drop any objects into 
the air outlets or vents.

x

 

Do not place objects or let any person sit on top of the unit.  

x

 

Only use in the upright position on a flat, level surface and provide at 
least 20 inches of clearance from any walls or objects.  

x

 

Route the power cord carefully to avoid a tripping hazard.  

x

 

This unit is intended for domestic use only. Do not use the portable air 
conditioner for industrial or commercial use.  Any other use may 
invalidate the warranty. 

RESET

TEST

Summary of Contents for AP14002HS

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP14002HS...

Page 2: ...door use only x Do not use the unit in extremely humid or wet environments x Do not spray water and wet the housing or control panel x Do not pull the unit by the cord x Always turn the unit off and u...

Page 3: ...LING THE WINDOW KIT 4 ATTACH THE WINDOW PANEL TO THE WINDOW PANEL 4 NOTES ABOUT THE EXHAUST HOSE 6 CONTROL PANEL OVERVIEW 7 CONTROL PANEL OPERATING INSTRUCTIONS 7 REMOTE CONTROL OVERVIEW 8 REMOTE CONT...

Page 4: ...back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warran...

Page 5: ...Back View Parts Key 1 Control Panel 2 Air Outlet Vent 3 Castors 4 Remote Holder 5 Upper Air Filter Grille Intake 6 Handle 7 8 Power Cord Hooks 9 Power Cord 10 Air Outlet Heat Exhaust 11 Lower Air Filt...

Page 6: ...xtend the exhaust hose at least 6 and insert it to the outdoor exhaust hose outlet at the back of the air conditioner 2 Attach the round connector to the opposite end of the exhaust hose Suggested Too...

Page 7: ...t See the power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window...

Page 8: ...l you have a tight connection Connect your Exhaust Hose to the Exhaust Hose Adapter by screwing the hose to the adapter until you have a tight connection Lastly connect the Exhaust Hose Adapter to the...

Page 9: ...or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the Unit When the portable...

Page 10: ...time for High Fan indicated on LCD as F3 Under Dehumidifying Mode Fan is automatically working in low speed Up and Down Press to increase or decrease the set temperature Press down at the same time an...

Page 11: ...his key under cooling dehumidifying and energy saver mode It will work on low speed to blow accumulated condensate water to clean C F Press this key to choose Celsius and Fahrenheit This unit has auto...

Page 12: ...etc in the room x Close all windows and doors x Use the unit in a contained room For example a room with four walls and a ceiling instead of a partitioned studio or warehouse x Make sure the unit is...

Page 13: ...um cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre fil...

Page 14: ...surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuous metallic knocki...

Page 15: ...room is too large Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and win...

Page 16: ...4002HS Voltage Frequency AC 115V 60Hz Input Power Cooling 1332W Input Power Heating 1255W Current 12A BTU 14 000 Color Silver with Stainless Steel Front Coolant Quantity R 410A 21 5oz Timer 24 Hour Di...

Page 17: ...er installation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacem...

Page 18: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: