EdgeStar AP14002HS Owner'S Manual Download Page 15

EdgeStar Portable Air Conditioner  

 

12 

Troubleshooting continued 

Issue Possible 

Cause 

Solution 

My air conditioner is 
not cooling at all. 

Unit is not operating in 
cooling mode. 

Set the unit to be in 
cooling mode, and 
lower the set 
temperature (pg. 13). 

The compressor is not 
on.

The compressor may 
take up to 3 minutes to 
turn on, or longer if it is 
too warm. 

The ambient 
temperature is too 
high.

Lower the room 
temperature to be 
below 90°F degrees. 

The filter may be dusty 
or blocked. 

Clean the filters.  
(pg. 16) 

Blocked exhaust port. 

Remove any 
obstructions in the 
exhaust hose and port.

My air conditioner 
blows cold air, but 
does not lower the 
room temperature. 

The unit is not vented. 

The unit must be 
vented. (pg. 4) 

The area of the room 
is too large. 

Minimize the size of 
the area to be cooled, 
i.e. adding a drop 
ceiling. Use more than 
one unit to cool the 
area, or use a larger 
unit.

Open windows and 
doors.

Close any open doors 
and windows. 

Too many heat 
sources. 

Remove or shut off 
additional heat 
sources such as radio 
equipment, servers, 
etc. 

The room/garage may 
be inadequately 
insulated. 

Properly insulate the 
room to be cooled, i.e. 
using fiberglass. 

The ambient 
temperature is too 
high.

The unit may not work 
if the room 
temperature is above 
90°F.

Direct sunlight is 
heating the room. 

Close curtains or pull 
down blinds, and 
minimize the direct 
sunlight into the room. 

The filter may be dusty 
or blocked. 

Clean the filter and 
replace it if needed. 

Dirty condenser coils. 

Carefully vacuum the 
coils clean. 

Obstructed air intake 
or exhaust ports. 

Remove anything 
blocking the ports. 

NOTE:

 If the ambient 

temperature is above 90°F the 
unit may not blow cold air. 

Summary of Contents for AP14002HS

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP14002HS...

Page 2: ...door use only x Do not use the unit in extremely humid or wet environments x Do not spray water and wet the housing or control panel x Do not pull the unit by the cord x Always turn the unit off and u...

Page 3: ...LING THE WINDOW KIT 4 ATTACH THE WINDOW PANEL TO THE WINDOW PANEL 4 NOTES ABOUT THE EXHAUST HOSE 6 CONTROL PANEL OVERVIEW 7 CONTROL PANEL OPERATING INSTRUCTIONS 7 REMOTE CONTROL OVERVIEW 8 REMOTE CONT...

Page 4: ...back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warran...

Page 5: ...Back View Parts Key 1 Control Panel 2 Air Outlet Vent 3 Castors 4 Remote Holder 5 Upper Air Filter Grille Intake 6 Handle 7 8 Power Cord Hooks 9 Power Cord 10 Air Outlet Heat Exhaust 11 Lower Air Filt...

Page 6: ...xtend the exhaust hose at least 6 and insert it to the outdoor exhaust hose outlet at the back of the air conditioner 2 Attach the round connector to the opposite end of the exhaust hose Suggested Too...

Page 7: ...t See the power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window...

Page 8: ...l you have a tight connection Connect your Exhaust Hose to the Exhaust Hose Adapter by screwing the hose to the adapter until you have a tight connection Lastly connect the Exhaust Hose Adapter to the...

Page 9: ...or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the Unit When the portable...

Page 10: ...time for High Fan indicated on LCD as F3 Under Dehumidifying Mode Fan is automatically working in low speed Up and Down Press to increase or decrease the set temperature Press down at the same time an...

Page 11: ...his key under cooling dehumidifying and energy saver mode It will work on low speed to blow accumulated condensate water to clean C F Press this key to choose Celsius and Fahrenheit This unit has auto...

Page 12: ...etc in the room x Close all windows and doors x Use the unit in a contained room For example a room with four walls and a ceiling instead of a partitioned studio or warehouse x Make sure the unit is...

Page 13: ...um cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre fil...

Page 14: ...surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuous metallic knocki...

Page 15: ...room is too large Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and win...

Page 16: ...4002HS Voltage Frequency AC 115V 60Hz Input Power Cooling 1332W Input Power Heating 1255W Current 12A BTU 14 000 Color Silver with Stainless Steel Front Coolant Quantity R 410A 21 5oz Timer 24 Hour Di...

Page 17: ...er installation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacem...

Page 18: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: