10 

Maintenance

Clean the air conditioner and filters regularly to maximize 
performance and efficiency, and prolong the unit’s life. Be sure to 
always unplug the air conditioner from the power outlet before 
cleaning. 

Use a soft dry cloth to wipe the body clean. If necessary, use 
lukewarm water to dampen a cloth to clean the unit. 
Use a soft bristle brush to clean between the vents.
Carefully use a vacuum cleaner to clean the condenser coils. 

Never use abrasive chemicals, volatile substances, gasoline, 
detergents, chemically treated cloths, or other cleaning solvents 
that may damage the cabinet exterior. 

Never spray water directly on the unit. 

To clean the pre-filter, follow the steps below: 

1) Power off the unit and remove the pre-filter.
2) Use a vacuum cleaner or tap the filter lightly to remove loose 
dust and dirt, then rinse thoroughly under lukewarm running water 
(below 104°F). You may use a mild soap and water solution if 
needed. Allow the pre-filter to air dry in a cool and shaded place. 
Dry thoroughly before reinstalling.  

Clean the pre-filter periodically. If the unit is used in a dusty 
environment you may need to clean it on a weekly basis. 

If you are not going to be using the unit for an extended period of 
time, follow the instructions below before storing your unit: 

1) Drain all the water from the unit’s reservoir. Operate the unit in 
fan mode for a few hours to thoroughly dry any moisture left on the 
coils inside the unit.  
2) Power off the unit, and clean or change the filters. 
3) Unplug and carefully wind the power cord. 
4) Remove the exhaust hose and duct connectors and keep them 
in a safe place. 

Cleaning the unit 

Cleaning the pre-filter 

Preparation for Storage 

Warning

: Never operate 

the unit without the pre-
filter.

Summary of Contents for AP14002HS

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP14002HS...

Page 2: ...door use only x Do not use the unit in extremely humid or wet environments x Do not spray water and wet the housing or control panel x Do not pull the unit by the cord x Always turn the unit off and u...

Page 3: ...LING THE WINDOW KIT 4 ATTACH THE WINDOW PANEL TO THE WINDOW PANEL 4 NOTES ABOUT THE EXHAUST HOSE 6 CONTROL PANEL OVERVIEW 7 CONTROL PANEL OPERATING INSTRUCTIONS 7 REMOTE CONTROL OVERVIEW 8 REMOTE CONT...

Page 4: ...back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warran...

Page 5: ...Back View Parts Key 1 Control Panel 2 Air Outlet Vent 3 Castors 4 Remote Holder 5 Upper Air Filter Grille Intake 6 Handle 7 8 Power Cord Hooks 9 Power Cord 10 Air Outlet Heat Exhaust 11 Lower Air Filt...

Page 6: ...xtend the exhaust hose at least 6 and insert it to the outdoor exhaust hose outlet at the back of the air conditioner 2 Attach the round connector to the opposite end of the exhaust hose Suggested Too...

Page 7: ...t See the power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window...

Page 8: ...l you have a tight connection Connect your Exhaust Hose to the Exhaust Hose Adapter by screwing the hose to the adapter until you have a tight connection Lastly connect the Exhaust Hose Adapter to the...

Page 9: ...or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the Unit When the portable...

Page 10: ...time for High Fan indicated on LCD as F3 Under Dehumidifying Mode Fan is automatically working in low speed Up and Down Press to increase or decrease the set temperature Press down at the same time an...

Page 11: ...his key under cooling dehumidifying and energy saver mode It will work on low speed to blow accumulated condensate water to clean C F Press this key to choose Celsius and Fahrenheit This unit has auto...

Page 12: ...etc in the room x Close all windows and doors x Use the unit in a contained room For example a room with four walls and a ceiling instead of a partitioned studio or warehouse x Make sure the unit is...

Page 13: ...um cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre fil...

Page 14: ...surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuous metallic knocki...

Page 15: ...room is too large Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and win...

Page 16: ...4002HS Voltage Frequency AC 115V 60Hz Input Power Cooling 1332W Input Power Heating 1255W Current 12A BTU 14 000 Color Silver with Stainless Steel Front Coolant Quantity R 410A 21 5oz Timer 24 Hour Di...

Page 17: ...er installation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacem...

Page 18: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: