Information and recommendations 

 

 

Pursuant  to  European  directive  UTE  C00-200,  incorporating  directives  89/336  EEC  and 
92/31 EEC, PACKSOLO complies with the following standards: 

 

NF EN 50081-1 governing electromagnetic radiation, and 

 

NF EN 50082-1 governing electromagnetic susceptibility. 

 

 

Cabling  recommendations:

  the  cables  used  to  connect  readers,  the  network  and  other 

peripherals  must  be  installed  in  accordance  with  the  instructions  for  Level  2  (protected 
environment) of standard NF EN 61000-4-4. 

 

This product must be installed by an approved company.

 Incorrect installation and usage 

may  result  in electric  shock  or  fire.  Before  installing  the  product,  read  the  technical 
information and comply with the recommendations. 

 

Once the power is turned off, all the internal capacitors will discharge themselves to a 
safe level after 60 seconds under normal conditions. However, in the event of a power 
failure,  the  charge  may  be  maintained  for  much  longer  and  suitable  precautions 
should be taken before handling the product. 

 

Summary of Contents for PACK SOLO

Page 1: ...Access control PACK SOLO Standalone Biometric reader Technical manual...

Page 2: ...ic door lock triggered by a power failure 10 9 Standard door activator triggered by a voltage pulse 11 Initial power on Factory configuration 12 Installation of more than one reader on the same site 1...

Page 3: ...Technical manual PACKSOLO V1 5 p 3 24 Warning Caution This product is designed to work only in a standalone mode...

Page 4: ...INNOVATIONS The entire EDEN INNOVATIONS team would like to thank you for your interest as well as your confidence in our security solution We hope that you will be completely satisfied with the level...

Page 5: ...nstalled in accordance with the instructions for Level 2 protected environment of standard NF EN 61000 4 4 This product must be installed by an approved company Incorrect installation and usage may re...

Page 6: ...ousing dimensions 119 x 77 x 40 mm Operating temperature 20 C to 50 C 4 F to 122 F Fingerprints 500 templates 2 Remote control opening Maximum power consumption 200mA 12V Power supply voltage 9 14VDC...

Page 7: ...airs recommended 1200 m 2730 ft 0 6 mm 1 30 in SYT recommended Characteristic Sensitive connection Screen Mandatory To achieve 1200 m 2730 ft you need to install a 120 resistor at each end of the netw...

Page 8: ...mmon earth is connected between the control module and the control unit If the input is set to 0V The alarm is activated opening impossible mandatory inactivation of the alarm before opening using an...

Page 9: ...ion switches Switches 1 and 2 configuration of the time delay for the opening control Switch 3 configuration of the Alarm activation inactivation output activation inactivation of a third party intrus...

Page 10: ...er s power supply it is obligatory to follow the wiring diagram above 8 Electromagnetic door lock triggered by a power failure Note In order to avoid any random malfunctions that may interfere with th...

Page 11: ...t use of the system caused by return currents it is essential to use and connect the non return diodes supplied with the product in accordance with the wiring diagram above Even when using an addition...

Page 12: ...eed to register the 3 configuration cards Add Add Alarm and Delete with the reader in order to activate it To do this follow the procedure below After this stage your product is activated Present the...

Page 13: ...ou use the badge with fingerprint access for several readers on the same site so as to remember the same code for each reader therefore to not repeat the addition of badges on each reader you must onl...

Page 14: ...for the user you wish to add You have 10 seconds to present the first finger of the user to be added 3 times You have 10 seconds to present the second finger of the user to be added 3 times if you onl...

Page 15: ...st finger of the user to be added You have 10 seconds to present 3 times the second finger of the user to be added if you only want to enrol one finger wait for 10 seconds Present the Add badge at the...

Page 16: ...ccess finger of the user to be added 3 times You have 10 seconds to present the alarm finger of the user to be added 3 times if you do not enrol a second fingerprint the badge added will be encrypted...

Page 17: ...present the access finger of the user to be added 3 times You have 10 seconds to present the alarm finger of the user to be added 3 times if you do not enrol a second fingerprint the user added will...

Page 18: ...ngerprints and badges only Present the Delete badge You have 10 seconds to present one of the 2 fingers of the user to be deleted If the user is recognised he she will immediately be deleted Present t...

Page 19: ...gs in order to register a new set of configuration badges This process will delete all the users fingerprints only and badges To restore to factory settings Switch off the power Press the RESET button...

Page 20: ...y configuration waiting for configuration badges cards Add Add Alarm Delete Flashing Off Normal operation waiting for a user On Door open On Alarm activated Refusing standard users and waiting for ina...

Page 21: ...Technical manual PACKSOLO V1 5 p 21 24 Connector blocks...

Page 22: ...Technical manual PACKSOLO V1 5 p 22 24 Check list Pack SOLO Serial number ID number Gasket Torx bit Torx screw Bag Wall seal...

Page 23: ...Technical manual PACKSOLO V1 5 p 23 24 Technical Support hotline eden innovations com Notes...

Page 24: ...Zone Commerciale et Artisanale 670 route de Berre 13510 EGUILLES France www eden innovations com...

Reviews: