background image

How to Fill Nitrous Bottles (C

ONTINUED

 

4.    Tighten line.  

5.    Place the cylinder on the scale and note weight.  There will be a slight weight increase due to nitrous control 

valve assembly.  

6.    Fully open the valve on the Nitrous Oxide source bottle. 

7.    Slowly Open the nitrous control valve assembly.  

8.    At this point, it is recommended to carefully loosen the line leading to the cylinder to be filled until you hear 

a hissing sound followed by a whitish cloud of liquid nitrous.  This ensures that there is liquid in the line as 

well as ensuring that the source bottle is not empty.  

9.    When this is seen, re-tighten the line. 

10.  Fully open the valve on cylinder to be refilled.  Wait for pressure in the source bottle and bottle being filled 

to equalize.  Note the scale reading. 

11.  Open the air pressure control valve on the compressed air on/off valve assembly.  Watch the scale reading. 

12.  Close the air pressure valve when cylinder being filled reaches its full weight. 

 

Note:   

If cylinder being refilled reaches 1100 psi before the full weight of the bottle is reached, stop the 

pump by turning off the compressed air valve.  Invert the bottle and repeat this several times until 

you feel the bottle temperature drop.  You can then turn the pump back on and continue pumping.  

Also, as the pressure creeps up in the bottle being filled, you may be able to hear the nitrous pump 

slow down.  This is normal as it is now trying to push the liquid nitrous into the now pressurized 

(more dense) liquid in the bottle.  At this point, is may help to invert the bottle while the pump is on 

so that the new liquid now pushing through the gaseous (less dense) nitrous liquid in the bottle. 

 

13.  Close the valve on cylinder being filled. 

14.  Close the valve on nitrous control valve assembly.  

15.  Slowly loosen the line from cylinder being filled until you hear a light hissing noise. 

16.  Allow the all nitrous pressure to vent from the line.  This should only take a few seconds.  

If hissing persists, tighten line and return to step 13. 

17.  Close the valve on the nitrous oxide source bottle.  

18.  While holding the nitrous control valve assembly line pointed away from yourself, slowly open the valve on 

the nitrous control valve assembly just enough to relieve contents left in feed line.  

 

 

You have now completed the refill of the bottle. 

Page 7 

Edelbrock Nitrous Systems  

2700 California Street 

Torrance, California 90503 

Tech Line (800) 416-8628 

Tech Fax (310) 972-2730

 

Rev. 12/00 

Summary of Contents for Nitrous Refill Station 78000

Page 1: ...EDELBROCK NITROUS REFILL STATION 78000 Edelbrock Nitrous Systems 2700 California Street Torrance California 90503 Tech Line 800 416 8628 Tech Fax 310 972 2730 Rev 12 00...

Page 2: ...General Warranty It is the constant endeavor of Edelbrock Corporation to give our customers the highest quality products obtainable Edelbrock warrants each new product except Performer Series Carbure...

Page 3: ...y created for automotive applications and is available for sale to the public at many speed shops across the USA Safety Steps For Working With Nitrous Oxide 1 Never inhale Nytrous Plus Nitrous oxide N...

Page 4: ...gh most welding or scuba supply shops for a minimal charge 8 Never fill a bottle that has been altered modified dented or appears to be heated by a open flame 9 Always verify that a pressure release d...

Page 5: ...NPT female Reducer Bushings 1 3 8 NPT male x 1 4 NPT female Reducer Bushings 2 6AN Bottle Nut 1 326 to 4AN Adapter 2 Washer Bottle Nut 1 326 to 4AN Adapter Nut 1 4AN 12 Hose Blue 1 6AN 12 Hose Blue 1...

Page 6: ...near enough to the where transfer pump will be mounted for the 6 AN 6 ft hose to reach from the source bottle valve to the transfer pump Note Always use Teflon pipe sealant on all pipe NPT fittings 5...

Page 7: ...Never fill any cylinder above the full weight as stated on the cylinder label as weight of cylinder and gas 1 Check to be certain that the bottle you are about to fill is within the current hydro test...

Page 8: ...rt the bottle and repeat this several times until you feel the bottle temperature drop You can then turn the pump back on and continue pumping Also as the pressure creeps up in the bottle being filled...