background image

Thank You…. 

…for purchasing an Edelbrock Nitrous Oxide Refill Station. 

 

Nitrous Oxide injection is one of the most exciting performance enhancements, for the dollar invested, on the 

market today.  With the use of nitrous oxide come some important safety considerations.  This manual has been 

written to help you during the installation and use of your Edelbrock Refill Station.  Please read it completely before 

you use your system.  Please pay close attention to the safety information at the beginning of each section.   

 

 

Please take the time to read and understand the following…. 

 

By setting up your Edelbrock Refill Station, you indicate you have read this document and you agree with the terms 

stated below: 

 

It is the responsibility of the purchaser to follow  all installation instruction guidelines and safety  

procedures supplied with the Edelbrock Refill Station.   

 

Edelbrock Corporation assumes no responsibility for damages occurring from misuse, abuse, improper installation, 

improper operation, lack of responsible care, or all previously-stated reasons resulting from incompatibility with 

other manufacturer’s products and/or systems. 

 

Edelbrock Corporation neither recommends nor condones the use of products manufactured or sold by Edelbrock 

Corporation for use on vehicles, which may be driven on public roads or highways, and assumes no responsibility for 

damages incurred by such use. 

 

Edelbrock Corporation assumes no responsibility for damages incurred by the use of products manufactured or sold 

by Edelbrock Corporation on vehicles used for competition or racing. 

 

 

Edelbrock General Warranty 

 

It is the constant endeavor of Edelbrock Corporation to give our customers the highest quality products obtainable. 

Edelbrock warrants each new product, except Performer Series Carburetors, Race Division Parts, Tubular Exhaust 

Systems, RPM Series Mufflers, Cat-Back Systems and Performer IAS Shock Absorbers which are warranted 

separately, to be free from defects in both workmanship and material for a period of one (1) year from the date of 

purchase, provided that the product is properly installed, subjected to normal use and service and that the product 

is not modified or changed in any way, negligence by customer or installer or used for racing or competition 

purposes. 

 

Our warranty service and repair facility is located at 2700 California Street, Torrance, California 90503.  Customers 

who believe they have a defective product should either return it to the dealer from which it was purchased or ship 

it directly to Edelbrock along with proof of purchase and a complete description of the problem.  The product must 

be returned freight pre-paid.  If a thorough inspection of the product by the factory indicates defects in 

workmanship or material, our sole obligation shall be to repair or replace the product.  Warranty covers only the 

product itself and not the cost of installation or removal. 

 

Edelbrock Corporation shall not be liable for any and all consequential damages occasioned by the 
breach of any written or implied warranty pertaining to this sale in excess of the purchase price of the 
product sold. 
 
If you have any questions regarding a product or installation, please contact our Technical  
Department, toll free at 1-800-416-8628 from 7:00am to 5:00pm PST, Monday through Friday. 

 

Thank you again for choosing Edelbrock Nitrous Systems. 

Page 1 

Summary of Contents for Nitrous Refill Station 78000

Page 1: ...EDELBROCK NITROUS REFILL STATION 78000 Edelbrock Nitrous Systems 2700 California Street Torrance California 90503 Tech Line 800 416 8628 Tech Fax 310 972 2730 Rev 12 00...

Page 2: ...General Warranty It is the constant endeavor of Edelbrock Corporation to give our customers the highest quality products obtainable Edelbrock warrants each new product except Performer Series Carbure...

Page 3: ...y created for automotive applications and is available for sale to the public at many speed shops across the USA Safety Steps For Working With Nitrous Oxide 1 Never inhale Nytrous Plus Nitrous oxide N...

Page 4: ...gh most welding or scuba supply shops for a minimal charge 8 Never fill a bottle that has been altered modified dented or appears to be heated by a open flame 9 Always verify that a pressure release d...

Page 5: ...NPT female Reducer Bushings 1 3 8 NPT male x 1 4 NPT female Reducer Bushings 2 6AN Bottle Nut 1 326 to 4AN Adapter 2 Washer Bottle Nut 1 326 to 4AN Adapter Nut 1 4AN 12 Hose Blue 1 6AN 12 Hose Blue 1...

Page 6: ...near enough to the where transfer pump will be mounted for the 6 AN 6 ft hose to reach from the source bottle valve to the transfer pump Note Always use Teflon pipe sealant on all pipe NPT fittings 5...

Page 7: ...Never fill any cylinder above the full weight as stated on the cylinder label as weight of cylinder and gas 1 Check to be certain that the bottle you are about to fill is within the current hydro test...

Page 8: ...rt the bottle and repeat this several times until you feel the bottle temperature drop You can then turn the pump back on and continue pumping Also as the pressure creeps up in the bottle being filled...

Reviews: