5. The inverter output socket or terminal can only be connected to the appliance with the matching voltage. If the

customer connects the 110-120V appliance to the 230V inverter outlet, it may cause the appliance to burn out.6. The

AC output can only be connected to the electrical appliances. If connected to grid or generator, it may burn electronic

components. When this happens, a crack sound will be heard and smoke will be seen.

Should any of above cases occur here is the proper operation: first turn the inverter off; then disconnect the battery
cable; finally disconnect the appliances when smoke dissipates. Please feel free to contact Customer Service for
technical guide or repair service. (When the part in the inverter burns out, a crack sound will always be heard and
smoke seen. Please keep calm and follow the step above. Attention: please don't use water to irrigate the inverter or it
will cause more loss.)

19. DISPOSAL

Do not dispose the product in the household waste. Please dispose it according to the disposal regulations for electronic

waste in your country.

20. WARRANTY

Warranty for the product is one year starting from the date of purchase.

21. DISCLAIMER OF WARRANTIES

By damage of the unit in case of faulty installation, incorrect connection, misuse or abuse of the equipment will void the

warranty.

Incorrect repairs by unauthorized persons / workshops on the unit also lead to loss of warranty.

22. COMPENSATION

If not satisfied with the product, the product can be replaced within 7days (from date of delivery). When the casing or

packaging of the products is damaged, it will not be replaced for free.

Manufacturer:

Chang Tian Electrical Technology Co., Ltd

Address

: HaiXiaDaSha 502WushigangGongYeQu, DongchengDistrict,DongGuanCity,GuangDong Province,52300,China.

Email:

[email protected]

Designed in Germany, Made in China

visit our official website for more information

Summary of Contents for DPP10

Page 1: ...COPYRIGHT EDECOA ALL RIGHT RESERVED PSW EU V2 7 English 1 15 USER MANUAL Model DPP10 DPP15 DPP20 DPP25 DPP30 DPP35 DPP50 Language English...

Page 2: ...equirements 5 4 Opening the device 5 5 Ventilation 5 6 Connection 5 7 About the remote controller 6 8 Technical data Pure sine wave 8 9 How to select the proper inverter you need 8 11 How to choose th...

Page 3: ...ent The inverters are not Uninterruptible Power Supply 3 INSTALLATION 3 1 Background Do not install the inverter on flammable building materials Do not install the inverter in areas where flammable or...

Page 4: ...vironment requirements Ambient temperature should be kept below 50 to ensure the best inverter operating conditions and extend its service life Inverter should be installed in a well ventilated enviro...

Page 5: ...gative pole Use the supplied cable from the manufacturer or at least those with the same or larger cross section Keep these connections as short as possible it will flow considerable current depending...

Page 6: ...ual Power Automatic Transfer Switch ATS The ATS mainly used for testing whether normal N or spare R power is normal or not Here is the compatible specification 1 2P 230V 50HZ Travel switch includes sh...

Page 7: ...that the battery power indicator light maybe not correct Note If the remote controller can t work properly please try to replace the remote cable first ET RC remote controller 1 ON OFF switch press 3s...

Page 8: ...e remote controller can t work properly please try to replace the remote cable first 8 TECHNICAL DATA PURE SINE WAVE 9 HOW TO SELECT THE PROPER INVERTER YOU NEED Dependent of the devices you want to o...

Page 9: ...00W 11 HOW TO CHOOSE THE PROPER CABLE Inverters should be attached directly to the battery The wire size depends on the distance between the battery and inverter The following is a reference to the ca...

Page 10: ...multiplied by the number of parallel batteries For example four 12V 60AH batteries are connected in parallel and 500W of load can be used continuously for 1 h 12 min 4 4 h 48 min The above is the time...

Page 11: ...ations Note If you intend to use power tools for commercial use or any load of 200W for more than 1 hour regularly between battery recharging we recommend installing an auxiliary battery to provide po...

Page 12: ...erminal Battery input Battery input Fans 11 LED Status Display 14 HOW TO CONNECT TWO OR MORE BATTERIES Connected in parallel same voltage doubled AH Connected in series double voltage same AH Output s...

Page 13: ...e control If the temperature in the unite reaches 45 C the fan will start and cool down the device Over temperature protection when the inside temperature is over 75 the inverter will shut down an ala...

Page 14: ...uction voltage there is no current leakage This is normal Inverter output communication does not distinguish hotline and neutral line if you need to distinguish the hotline and neutral line please con...

Page 15: ...follow the step above Attention please don t use water to irrigate the inverter or it will cause more loss 19 DISPOSAL Do not dispose the product in the household waste Please dispose it according to...

Reviews: