TriTrax™ 200 Vertical Crawler
Document: UMDT017749.docm
Revision: A02
Created by: JS
Date: 13 Apr 2021
IPN: 3094329-A02
Source Location: C:\ePDM\ISLEng\Products\DT-VersaTrax100MkII\Manuals\UMDT017749.docm
Page 16 of 36
User Ma
nual
Note:
Never use WD-40 or similar solvent-based fluids on connectors or crawlers. These will cause the
rubber parts of the connector or crawler to soften and swell rendering them inoperable.
SubConn Connector: Lubrication and Cleaning
•
Periodically apply Molykote 111 silicone grease or equivalent before mating connectors
•
For dry mate connections, a layer of grease corresponding to 1/10 the socket depth should be
applied to the female connector
•
After greasing, fully mate the male and female connector and remove excess grease from the
connector joint
•
General cleaning and removal of sand or mud on a connector should be performed using a
spray-based contact cleaner like isopropyl alcohol
Impulse Connector: Lubrication and Cleaning
•
Lubricate mating surfaces regularly with 3M Silicone spray or equivalent, DO NOT GREASE
•
Lubricate O-rings with Molykote 111 or equivalent
•
Use dust caps to protect connectors wherever possible
•
Clean connectors with soap and fresh water, rinse out with alcohol and allow connector to air
dry before using.