Eddyfi Technologies LYNCS-CM User Manual Download Page 19

18 

 

LYNCS System components 

 

LYNCS-FULL 

Nanuk transport PELI-CASE 

Umbilical (5m or 15m / 16.4ft or 49.2ft) 

Hose guides (4) 

LYNCS Frame - 

412mm / 16.2”

  Cable management sleeve 

Portable site bag 

Inner toolpost (2) 

Wedge mounting kit 

Waterbox 

Outer toolpost (2) 

Irrigation kit 

Waterbox wedge - 15mm & 30mm  

Medium rails - 

500mm / 19.7”

  Cable guides (4) 

Waterbox Mount 

Large rails 

 Metric 667mm 

(2) / Imperial 26.6” (2)

 

Removable central handle 

Universal straps (Pre-Amp mounting) 

Waterbox foam seals (25) 

 

 

LYNCS-CM 

Nanuk transport PELI-CASE 

Cable management sleeve 

Portable site bag 

LYNCS Frame - 

412mm / 16.2”

 

Hose guides (4) 

Waterbox 

Large rails 

 Metric 667mm (2) /  

Cable guides (4) 

Waterbox wedge - 15mm & 30mm  

Imperial 26.6” (2)

 

Removable central handle 

Waterbox Mount 

Umbilical (5m or 15m / 16.4ft or 49.2ft) 

 

Waterbox foam seals (25) 

 

 

LYNCS-WI 

Nanuk transport PELI-CASE 

Umbilical (5m or 15m / 16.4ft or 49.2ft) 

Hose guides (4) 

LYNCS Frame - 

412mm / 16.2”

  Cable management sleeve 

Removable central handle 

Inner toolpost (2) 

Wedge mounting kit 

Cable guides (4) 

Outer toolpost (2) 

Irrigation kit 

 

Medium rails - 

500mm / 19.7”

  Universal straps (Pre-Amp mounting) 

 

  

 

 

 

 

 

 

 

 

 

Summary of Contents for LYNCS-CM

Page 1: ...e cannot accept either legal responsibility or any liability for any incorrect statements which may remain and their consequences The following documentation is protected by copyright All rights reser...

Page 2: ...eral 3 Safety Markings and Symbols 3 Copyrights 3 LYNCSTM 4 LYNCSTM Scanner Frame Overview 5 LYNCS WI Overview 9 LYNCS WI Operation 14 LYNCS CM Overview 15 LYNCS CM Operation 17 LYNCS System component...

Page 3: ...2 General Precautions and Conventions...

Page 4: ...memory devices CRT monitors and medical or other electronics devices Strong magnetic fields pose a variety of risks especially to people who wear implanted cardiac devices like pacemakers and defibril...

Page 5: ...4 LYNCSTM...

Page 6: ...5 LYNCSTM Scanner Frame Overview Top View Side View Rear View...

Page 7: ...ief Point Used to provide strain relief on the encoder cable Prior to use ensure the encoder strain relief is applied Failure to do so could result in encoder cable or tractor unit damage Do not use s...

Page 8: ...oints Ensure the unit is tethered centrally to each attachment point at all times to prevent the scanner from falling Prior to use ensure the end caps and each tractor unit are securely fastened on th...

Page 9: ...176 F Minimum ambient temperature 20 C 4 F Maximum ambient temperature 50 C 122 F Minimum storage temperature 10 C 14 F Maximum storage temperature 40 C 104 F Circumferential scanning 100mm 4 to flat...

Page 10: ...9 LYNCS WI Overview Top View Tool Post Assembly Side View 6 7 8...

Page 11: ...ugged directly into the instrument and scanner Do not connect the adapter cable Connecting the adapter cable will enable Increment Encoder Reset functionality Adapter supplied with LYNCS FULL LYNCS CM...

Page 12: ...edge setup Tilt tool posts forwards when on the inspection surface 6 Removable central handle Accessory which can be mounted to scanner rail to aid stability and maneuverability Do not remove scanner...

Page 13: ...h of the tool post arms loosen thumbscrew at rear of tool post and move arm to desired position tighten thumbscrew to lock tool post arm in place Threaded holes are used to receive 5mm and 8mm diamete...

Page 14: ...s 40 mm 1 5 in Maximum number of tool posts 6 Tool posts compatibility Max wedge dimensions L87 W40 H45 5mm female wedge 8mm female wedge 5mm male pin wedge Weight scanner and 2 x tool posts 3 kg 6 6...

Page 15: ...cable management sleeve to strain relief points 9 Set toolpost in desired position along rail and lock into place If utilising outer toolposts do not set for pipe diameter until on the test item 10 T...

Page 16: ...r cable Adapter only supplied with LYNCS FULL LYNCS CM To use Pause Resume functionality remove the adapter cable and plug encoder cable directly into instrument and scanner 2 Rail Holes Waterbox moun...

Page 17: ...lever to unlock the spring loaded pin in the mechanism As the waterbox slides along the rail the pin will automatically drop into the next hole LYNCS CORROSION MAPPING SPECIFICATIONS Dimensions w d h...

Page 18: ...bration and complete remaining setup configuration 10 Tether scanner from both handles 11 Place onto test item to perform scan 12 Start data acquisition on instrument and move scanner forward 13 Apply...

Page 19: ...ting Waterbox foam seals 25 LYNCS CM Nanuk transport PELI CASE Cable management sleeve Portable site bag LYNCS Frame 412mm 16 2 Hose guides 4 Waterbox Large rails Metric 667mm 2 Cable guides 4 Waterbo...

Page 20: ...19 LYNCSTM Maintenance...

Page 21: ...adapter lead for Pause Resume functionality Connection issue Remove handle and check the white connector is securely connected See images 1 4 below Insufficient probe contact Weld Inspection Tool post...

Page 22: ...ket cap bolts and encoder housing 2 Carefully lift off handle cover making sure not to place excess strain on wiring 4 Remove Fischer socket nut and disconnect JST connector white part in image to rem...

Reviews: