16
4.
Corrosion mapping mount
Houses the supplied waterbox and clicks into each rail hole via the on-board lever lock along the length of
the rail. Lever lock on mount should sit on the same side as the rail with the drilled holes.
5.
Waterbox clamp
Tighten this thumbscrew to clamp waterbox in desired position. Unscrew to release the waterbox.
6.
Spring loaded lever lock
Turn the lever to unlock the spring-loaded pin in the mechanism. As the waterbox slides along the rail, the
pin will automatically drop into the next hole.
LYNCS CORROSION MAPPING SPECIFICATIONS
Dimensions (w × d × h)
742 × 198 × 109 mm (29.2 × 7.8 × 4.3 in)
Standard bar widths
412 mm (16.2 in) / Metric - 667 mm (26.2 in) / Imperial 675mm (26.6in)
Maximum scan width
510 mm (20.1 in)
Scanner weight:
without water box
2.7 kg (6 lb)
with water box
3.5 kg (7.7 lb)
Circumferential scanning
100 mm (4 in) to flat plate
Full specification sheet is available to download through the web address below;