Periodically apply Molykote 111 silicone grease or equivalent before mating connectors
•
For dry mate connections, a layer of grease corresponding to 1/10 the socket depth should
be applied to the female connector
•
After greasing, fully mate the male and female connector and remove excess grease from the
connector joint
•
General cleaning and removal of sand or mud on a connector should be performed using a
spray-based contact cleaner like isopropyl alcohol
Attaching the Drop Cone Assembly (Optional)
A drop cone assembly should be attached to the rear of the camera for drop camera configurations.
Always use the drop cone as the connector is not strong enough by itself for lifting applications.
To install the drop cone do the following:
1. Insert the tether cable through the cone and connect to the camera.
2. Align the recess with the purge valve as shown above.
3. Secure the drop cone with three M6 x 16mm SHCS.
4. Attach the Kellem
’s grip to the tow cable on the drop cone.
FIGURE 6: KELLEM
’S GRIP/TOW CABLE ASSEMBLY
FIGURE 5: ATTACHING THE DROP CONE ASSEMBLY