CONTROLS AND ACCESSORIES

SAFETY VALVE
Safety valve is designed to open automatically if boiler steam 

pressure exceeds pressure rating of valve (15 psig). Should 

it fail to open under this condition, shut down your boiler. If 

valve discharge occurs, or valve fails to open as described 

above, contact a qualified service technician to replace safety 

valve and inspect heating system to determine cause, as this 

may indicate equipment malfunction.

STEAM PRESSURE GAUGE
Boiler is equipped with pressure gauge installed. Gauge 

enables monitoring of the pressure in the system. If safety 

devices fail to shut off your boiler at proper settings, notify 

your serviceman immediately.

WATER LEVEL GAUGE
Boiler water level can be seen through glass tube in water 

level gauge at side of boiler. Correct cold boiler water level 

is stamped on side jacket panel. Check water level regularly 

for proper level.
Located on right side of boiler jacket panel, there are three 

holes for glass water level gauge. Top hole is common for 

both types of low water cut off, and is used for upper gauge 

glass fitting. Middle hole, 9” down from top hole, is used for 

bottom gauge glass fitting for the Model 67D-1 and 47-2 

float type low water cut off. Lowest hole, 12

1

/4” down from 

top hole, is used for bottom gauge glass fitting for Model 

PS-802 probe type low water cut off. Cover unused with 

sheet metal knockout.

STEAM PRESSURE CONTROL
Steam pressure limit control (pressuretrol) shuts off gas to 

main burners when steam pressure in boiler reaches cut-

off setpoint (i.e. sum of cut-in and differential setpoints). 

Burners refire when steam pressure drops to cut-in 

setpoint. System pressure requirements are based on size 

and condition of pipes, and load.

LOW WATER CUT-OFF 
Model 67D-1
Float operated switch which shuts down gas burner if water 

falls below visible bottom of gauge glass.
Probe Type Models
Electronic probe type LWCO. Probe is located inside boiler. 

LWCO will shut down burners if water loses contact with 

probe for 10 seconds.
Refer to manufacturer’s instructions (enclosed) for more 

information.

WATER FEEDER (Optional)
Model WF-2U-24 water feeder maybe used with either 

of the low water cutoffs listed. Water feeder maintains 

safe minimum water level. Keeps boiler running by 

compensating for minor evaporative steam leaks, and 

prevents freeze-ups if homeowners are away and return 

line leaks.
McDonnell and Miller Model 101 water feeders may be 

used, however water feed rates are too high and need to 

be regulated or throttled and wiring will have to be revised. 

Consult boiler manufacturer before using these or any 

other non-standard types of controls.
Automatic water feeder is safety device, not convenience 

item. It is not designed to maintain “normal” water line. 

Water feeder does not take place of responsible person 

monitoring and maintaining normal water line. Steam 

boilers require attention. 

VENT DAMPER
Automatic, motorized stack damper developed to increase 

efficiency of heating systems by reducing standby losses 

from boiler and conditioned air space. Damper closes 

chimney vent when burner is off and fully opens it when 

combustion is required.

ROLLOUT SWITCH
(FLAME ROLLOUT SAFETY SHUTOFF)
Rollout switch is temperature-sensitive fuse link device. 

Located on boiler base just outside fire box. In event of heat 

exchanger flueway blockage causing flame to roll out of 

fire box, fuse will blow, shutting down flow of gas to main 

burners. Fuse does not change in appearance when blown.
If rollout switch blows, replace with exact replacement. 

Check heat exchanger flueways for blockage when 

restoring system to operating condition. Do not operate 

system without rollout switch.

SPILL SWITCH
(BLOCKED VENT SAFETY SHUTOFF)
Spill switch is manual reset disc thermostat with fixed 

setpoint (280° F), and normally closed contacts. It is located 

at relief opening of draft diverter. In event of chimney or 

venting system blockage causing products of combustion 

to spill out of relief opening, spill switch disc heats up and 

spill switch contacts open, shutting down flow of gas to main 

burners by removing power to gas valve.
In event spill switch contacts open, reset button on back of 

switch will pop up. Manually reset spill switch after switch has 

cooled off, push reset button down. Check venting system 

and chimney for blockage when restoring system to operating 

condition. DO NOT operate boiler without spill switch.

Summary of Contents for Dunkirk Plymouth Steam PSB-3D

Page 1: ... ISO 9001 2008 Certified Company P N 14683003 Rev B 09 2013 ECR International Inc 2201 Dwyer Avenue Utica NY 13501 www ecrinternational com MODEL PSB Electronic Intermittent Ignition MODELS PSB 3D PSB 3DP PSB 4D PSB 4DP PSB 5D PSB 5DP PSB 6D PSB 6DP PSB 7D PSB 7DP PSB 8D PSB 8DP PSB 9D PSB 9DP ...

Page 2: ...L NUMBER 1 Dimensions Inches Intermittent Ignition w Vent Damper Flue Diameter A Width PSB 3D 5 11 PSB 4D 6 14 PSB 5D 6 17 PSB 6D 7 21 PSB 7D 7 24 PSB 8D 7 27 PSB 9D 7 30 Add 5 to height for Vent Damper 1 Add model number suffix P for Propane Gas ...

Page 3: ... Mbh Net AHRI Rating Sq Ft 1 PSB 3D 3 Natural Gas 75 62 82 7 47 196 Propane 70 58 82 7 44 183 1 PSB 4D 4 Natural Gas 112 91 82 0 68 283 Propane 105 85 80 4 64 267 1 PSB 5D 5 Natural Gas 150 122 82 0 92 383 Propane 140 114 80 6 86 358 1 PSB 6D 6 Natural Gas 187 153 82 0 115 479 Propane 175 143 80 9 107 446 1 PSB 7D 7 Natural Gas 225 183 82 0 137 571 Propane 210 171 81 1 128 533 1 PSB 8D 8 Natural G...

Page 4: ... and without incurring any obligation whatsoever Introduction Boiler is designed for use in closed heating systems where all steam is returned as condensate and make up water is minimal Boiler is not designed for or intended for use in open systems using 100 make up water Prior to Installation Verify correct boiler for type of gas being used natural or propane See Rating Plate Verify boiler size a...

Page 5: ...r any other gas appliance with improper methods or materials could result in death or serious injury due to fire or to asphyxiation from poisonous gases such as carbon monoxide which is odorless and invisible WARNING Fire explosion asphyxiation hazard Keep boiler area clear and free from combustible materials gasoline and other flammable vapors and liquids Modification substitution or elimination ...

Page 6: ... conditions of use Boiler location should not interfere with proper circulation of air Introduce outside air if normal infiltration does not provide necessary air Fresh Air for Combustion on page 11 6 Notify owner to keep air passages free of obstruction Ventilating and combustion air must enter boiler room without restrictions 7 Install boiler so automatic gas ignition system components are prote...

Page 7: ... or place any obstruction in discharge line Terminate freely to atmosphere where any discharge will be clearly visible and at no risk of freezing Allow complete drainage of valve and discharge line Install safety valve with spindle in vertical position Do not install shutoff valve between boiler and safety valve Support safety valve discharge piping Be short and straight as possible Terminate with...

Page 8: ...s from the header one for each main 6 All boilers in gravity return systems must be equipped with a Hartford Loop as shown in Figure 5 7 When piping the vertical risers from the boiler to the header the bottom of the header must be a minimum of 24 inches above the water level line on the right side of the boiler 8 Steam riser s and header shall be 2 pipe size 9 Equalizer line shall be minimum 1 pi...

Page 9: ...9 Figure 4 Recommended Near Boiler Piping Using One Supply Tapping SYSTEM PIPING ...

Page 10: ...LLATION SYSTEM PIPING Figure 6 Chilled Water Piping VALVES A B OPEN FOR HEATING CLOSE FOR COOLING VALVES C D CLOSE FOR HEATING OPEN FOR COOLING Figure 5 Recommended Near Boiler Piping Using Two Supply Tappings ...

Page 11: ...ater than 0 60 Room volume is greater than 21 cubic feet divided by ACH air changes per hour x Total Input Mbh C Refer to National Fuel Gas Code for opening requirements between connected indoor spaces All Outdoor Air Provide permanent opening s communicating directly or by ducts with outdoors A Two Permanent Opening Method Provide opening commencing within 12 inches of top and second opening comm...

Page 12: ...ould not be longer than 3 4 the chimney height HT Figure 7 page 13 Vent Pipe Fasten sections of vent pipe with 3 sheet metal screws at each joint to make piping rigid Support horizontal portions of vent system to prevent sagging Use stovepipe wires or metal strapping every 5 to support pipe from above Vent pipe through crawl space use double wall vent pipe Vent pipe passing through combustible wal...

Page 13: ...her gas burning appliance to their previous conditions of use 7 Any improper operation of the common venting system should be corrected so the installation conforms with the National Fuel Gas Code ANSI Z223 1 NFPA 54 When re sizing any portion of the common venting system the common venting system should be resized to approach the minimum size as determined using the appropriate tables in Chapter ...

Page 14: ...ion and for vent damper troubleshooting guide refer to manual packaged with vent damper Horizontal Installation To Boiler Vent Damper To Chimney NO NO YES YES Flow Install vent damper with actuator to sides of vent only Do not mount above or below vent To Chimney Flow Vent Damper To Boiler Actuator may be installer in any position Figure 9 Alternate Vent Damper Installation Do Not Install Here Cau...

Page 15: ...t or dampen excessive vibrations and prevent strain on gas connection Gas valve will not support piping weight Use thread joint compound pipe dope suitable for natural and liquefied petroleum gas Install field sourced manual main shutoff valve ground joint union and sediment trap upstream of gas valve See Figure 11 DANGER Fire Hazard Do not use matches candles open flames or other methods providin...

Page 16: ...cut off two wires are black One wire is located on secondary of 24 volt transformer second wire is located on pressure limit control F Boilers with PS 802 probe type low water cut off one wire is green and is located on terminal B of PS 802 second wire is black and located on pressure limit control VENT DAMPER Boiler is equipped with factory wired 4 pin molex harness that plugs into 4 pin molex re...

Page 17: ...rol knob slightly and turn clockwise to OFF Do not force For Your Safety Read Before Operating WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance is equipped with an ignition device which automatically lights burner Do NOT try to light this burner by hand Before operating smell all around app...

Page 18: ...own on left side of boiler Determine water level when boiler is off and cold when all water in the system is inside the boiler and return piping below water line and everything above water line is air no steam When boiler is making steam water level drops two to three inches below normal water line WARNING Burn Hazard Never run water into a hot empty boiler Failure to follow these instructions cou...

Page 19: ... inner cones in softer blue outer mantel with no yellow Remain still when observing main burner flames Check main burner orifices burner throat and flame ports for dust and lint obstruction if flame appearance is not correct Remove rollout shield if necessary to observe main burner flames Replace rollout shield after observation Gas Valve Safety Shutdown Test 1 Test ignition system safety shutoff ...

Page 20: ...power on and turn thermostat to call for heat C Gas valve opens for approximately 10 seconds time delay on probe type LWCO gas valve will close and red indicator illuminates on LWCO D When water is restored it waits 30 seconds before reactivating burner circuit Boiler Equipped With Optional WF 2U 24 Water Feeder E Continue thermostat call for heat after low water cut off recognizes low water condi...

Page 21: ...uild up Run connection from boiler drain valve to safe discharge point outside Shut off gas burners open drain valve allow all of water in boiler to drain out Close drain valve Allow boiler to cool slowly refill boiler to water line Repeat this step as many times as necessary until blow down water is clear 7 Following final blow down allow boiler to cool Add fresh water slowly up to normal water l...

Page 22: ...s bead of 400 F RTV silicone to four mounting surface flanges of flue collector Mount flue collector on heat exchanger Tighten nuts and bolts 6 Seal front edge and four corners of flue collector to heat exchanger with silicone sealant 7 Use flashlight to verify there are no gaps in silicone seal 8 Install draft diverter vent damper vent pipe and jacket top and front cover 9 Reassemble all parts 10...

Page 23: ...re joints Rollout switch blown Have your service technician check heat exchanger for blockage Chimney flue is blocked Spill switch contacts open requiring manual reset of spill switch Have your service technician check and correct chimney problem Vent damper not operating Consult troubleshooting guide packaged with vent damper IF BURNER IS NOISY Gas input amount is incorrect Contact your service t...

Page 24: ...is appliance must be replaced it must be replaced with type 105 C Thermoplastic wire or its equivalent Figure 13 Wiring Diagrams For Boilers With PS 802 Probe Type Low Water Cut Off Shown PS802 PS802 CG400 N 2 H 1 C P1 E P2 W A Terminals PS802 To CG400 Cross Reference ...

Page 25: ...any of the original wire as supplied with this appliance must be replaced it must be replaced with type 105 C Thermoplastic wire or its equivalent Figure 17 Wiring Diagrams For Boilers With 67D 1 Float Type Low Water Cut Off ...

Page 26: ...al Model WF 2U 24 water feeder maybe used with either of the low water cutoffs listed Water feeder maintains safe minimum water level Keeps boiler running by compensating for minor evaporative steam leaks and prevents freeze ups if homeowners are away and return line leaks McDonnell and Miller Model 101 water feeders may be used however water feed rates are too high and need to be regulated or thr...

Page 27: ...27 REPAIR PARTS ...

Page 28: ...28 REPAIR PARTS ...

Page 29: ...29 REPAIR PARTS ...

Page 30: ...30 REPAIR PARTS Safety Relief Valve 14 11 NPT X 4 Nipple PF 033 02 ...

Page 31: ...31 Date Service Performed Company Name Tech Initials Company Address Phone ...

Page 32: ...DUNKIRK BOILERS 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com ...

Reviews: