The EcoJump is designed 

to jump start 12V lead-acid 

batteries with voltage 

readings down to 3.2V. If 

your vehicle battery is below 

3.2V, the 

READY TO JUMP

 

LED will be OFF (even after 

connecting correctly to 

the POS and NEG battery 

terminals). This is an 

indication that the EcoJump 

cannot detect a battery.
If you need to jump start a 

battery below 3.2V, there is 

a Manual Override feature, 

which allows you to force ON 

the jump start function.

CAUTION:

 Use this mode 

with 

EXTREME CARE

. This 

mode is for 12V lead-acid 

batteries only. 

Both

 

the spark proof and 

reverse polarity protection 

features are disabled in 

Override Mode. 

Pay very close attention to 

the polarity of the battery 

before using this mode. Do 

NOT

 allow the positive and 

negative jump start clamps 

to touch or connect to each 

other as the product will 

generate sparks. This mode 

uses very high current (up 

to 600 Amps) that can 

cause sparks and high heat 

if not used properly. If you 

are unsure about using this 

mode, do 

NOT

 attempt and 

seek professional help.

Low-Voltage Vehicle Batteries & 

Manual Override

 - Use With Caution

  period. Allow the EcoJump 

  to rest for ten minutes 

  before attempting to jump 

  start the vehicle again.
  Once you have started 

  your vehicle, press the 

  Power Button on the 

  EcoJump to put it in 

  Standby Mode, unplug 

  the Jump Start Cables 

7

NOTE:

 When disconnecting, 

disconnect in the reverse 

sequence, removing the 

negative clamp first.

Jump Start

  Connect the Jump Start 

  Cables to the EcoJump.
  Press the 

Power Button

 

  to turn ON EcoJump unit, 

  when in Standby Mode 

  (if the EcoJump is OFF, 

 

PRESS AND HOLD

 the 

  Power Button to turn ON). 

 The 

Battery Level 

 Indicator

 lights and 

Power

 

 

Indicator

 light will 

  illuminate to show the 

  unit is on and ready for 

  use. If you are connected 

  to a 12V battery, one of 

 the 

Status Lights

 will 

  also illuminate:
 • 

READY TO JUMP:

 

GREEN

 light ON means 

 

EcoJump is ready to 

 

jump start your battery.

 • 

DISCONNECT!:

 

Something is connected 

 

incorrectly - 

Disconnect 

 

the clamps immediately!

 

 

RED

 light flashing 

 

means EcoJump is 

 

likely short circuited. 

RED

 

 

light ON means EcoJump 

 

is likely connected with 

 

reverse polarity. 

 • 

RECHARGE ECOJUMP:

 

YELLOW

 light ON means 

 

your EcoJump battery 

 

level is too low to use the 

 

jump start function. 

 

You must recharge before 

 

attempting to use as a 

 

jump starter.

  If the (

GREEN

READY TO 

 JUMP

 LED is lit, you are 

  ready to proceed.
  Make sure all of the 

  vehicle’s power loads 

  (headlights, radio, air

  conditioning, etc.) are 

  turned off before 

  attempting to jump start 

  the vehicle.
  Try starting the vehicle. 

  Most vehicles will start

  immediately; however, 

  some vehicles may 

  require the EcoJump to 

  be connected for up to 

  30 seconds before 

  starting. If the vehicle does 

  not start right away, wait 

  20-30 seconds before 

  trying again. Do 

NOT

 

  attempt more than three 

  consecutive jump starts 

  within a ten-minute 

3

4

  from the EcoJump 

  unit, and disconnect the 

  jump start clamps from 

  your vehicle (removing 

  the negative, 

BLACK

  clamp first). Remove the 

  EcoJump from the vehicle 

  engine compartment and 

  store in a safe place in your 

  vehicle, home, or office.

6

5

Summary of Contents for GDI-EXJMP1500

Page 1: ...Models GDI EXJMP1500 1520 User Guide EcoJump ...

Page 2: ...ndoors or outdoors and in land or water environments The device has been tested to IP67 waterproofing standards However the device is not intended for constant underwater use Always make sure the cap s covers s are clean free from sand or debris and correctly fitted The device will only meet IP67 ratings if all rubber seals gasket s and cap s covers s are in place If your device is exposed to salt...

Page 3: ...e could be potentially hazardous and cause fire or a spark 2 Never use your ECOXGEAR if you have dropped it or thrown it against a hard surface which may have destroyed the integrity of the housings or gaskets In the event of a severe impact to your unit please return the unit to Grace Digital to review for potential damage 3 Never open the auxiliary doors in a water environment This could cause w...

Page 4: ...CTIONS 1 RED Clamp to Terminal 2 BLACK Clamp to Terminal 3 Insert Jump Start Cable 4 Press Power Button 5 Check Status Lights POWER PRESS FLASHLIGHT HOLD HAZARD OVERRIDE Override Indicator Power Indicator Hazard Light Status Lights Battery Level Indicator PRESS AND HOLD to turn the hazard light ON OFF NOTE Unit must be ON for lights to function Override Use this function with EXTREME caution Refer...

Page 5: ...amp to the negative NEG N battery terminal or vehicle chassis PUSH TO SEAL About EcoJump The EcoJump is a portable waterproof lithium jump starter for vehicles with 12V lead acid batteries cars trucks boats ATVs motorcycles etc It is designed for easy safe use with built in reverse polarity short circuit protection The EcoJump has clearly labeled easy to understand buttons indicator lights and con...

Page 6: ...ump Start Connect the Jump Start Cables to the EcoJump Press the Power Button to turn ON EcoJump unit when in Standby Mode if the EcoJump is OFF PRESS AND HOLD the Power Button to turn ON The Battery Level Indicator lights and Power Indicator light will illuminate to show the unit is on and ready for use If you are connected to a 12V battery one of the Status Lights will also illuminate READY TO J...

Page 7: ...art if unit and or connections are wet or damp Important Maintaining Waterproofness If the caps are not properly closed your EcoJump is NOT watertight To ensure the unit is watertight waterproof ALWAYS CLOSE THE CAPS PROPERLY In order to ensure the unit is watertight close rubber caps PUSH along the EDGE of the RUBBER so that the caps are flush with the surface of the unit USB Charging Connections...

Page 8: ...P Status Lights will illuminate solid RED and YELLOW and the jump start connection port will become inactive After a period of time has passed to allow the EcoJump to cool down the Status Lights will turn off and the jump start connection will automatically re activate to send data to the EcoJump App on your smartphone whenever your smartphone is within range typically about 30 60ft You can config...

Page 9: ...Battery Temperature 77 F 25 C Recommended Min Storage Battery Temperature 4 F 20 C Operating Temperature 32 F to 113 F 0 C to 45 C Waterproof Dustproof Rating IP67 JUMP START INSTRUCTIONS 1 RED Clamp to Terminal 2 BLACK Clamp to Terminal 3 Insert Jump Start Cable 4 Press Power Button 5 Check Status Lights READY TO JUMP DISCONNECT RECHARGE ECOJUMP STATUS POWER PRESS FLASHLIGHT HOLD HAZARD OVERRIDE ...

Page 10: ...ualify for warranty protection Grace Digital reserves the right to replace any out of stock or discontinued product with a comparable product Discontinued products may not be available for warranty replacement Any contents are NOT covered by the limited manufacturer s warranty Warranty terms may be revised without notification at the discretion of the manufacturer Please visit www ecoxgear com for...

Reviews: