OUTDOOR UNIT INSTALLATION
6.
6.1 Installation Place
The outdoor unit should be installed in the location that
meets the following requiements:
There is enough room for installation and maintenance.
The air outlet and the air inlet are not impeded, and can not be
reached by strong wind.
It must be a dry and well ventilating place.
The support is flat and horizontal and can stand the weight of
the outdoor unit. And will no additional noise or vibration.
Your neighborhood will not feel uncomfortable with the noise
or expelled air.
It is easy to install the connecting pipes or cables.
Determine the air outlet direction where the discharged air is
not blocked.
There is no danger of fire due to leakage of inflamable gas.
The piping length between the outdoor unit and the indoor
unit may not exceed the allowable piping length.
In the case that the installation place is exposed to strong
wind such as a seaside, make sure the fan operating properly
by putting the unit lengthwise along the wall or using a dust
shield. (Refer to Fig. 6-1).
If possible, do not install the unit where it is exposed to direct
sunlight.
If necessary, install a blind that does not interfere with the air
flow.
During the heating mode, the water drained off the outdoor
unit. The condensate should be well drained away by the drain
hole to an appropriate place, so as not to interfere other people.
Select the position where it will not be subject to snow drifts,
accumulation of leaves or other seasonal debris. If unavoidable,
please cover it with a shelter.
Locate the outdoor unit as close to the indoor unit as possible.
X
O
Fig.6-1
Str
ong WI
nd
If possible, please remove the obstacles nearby to prevent the
performance from being impeded by too Little of air circulation.
The minimum distance between the outdoor unit and obstacles
described in the installation chart does not mean that the same
is applicable to the situation of an airtight room. Leave open
two of the three directions. (M,N,P) (Refore to Fig. 6-7, Fig. 6-8,
Fig. 6-9).
NOTE
The dimension of 12 and 24 are the same.
The dimension of 30 and 36 are the same.
The dimension of 48 and 60 are the same.
6.2 Figure of body size
Split type outdoor unit
1
Fig.6-2
Fig.6-3
Fig.6-4
B
C D
E
F
A
H
H
A
Table 5-1