CEILING FLOOR TYPE
ATTACHED FITTINGS
3.
INSPECTING AND HANDLING THE UNIT
4.
At delivery, the package should be checked and any damage
should be reported immediately to the the
service agent.
When handling the unit, take into account the following:
Fragile, handle the unit with care.
Keep the unit upright in order to avoid compressor damage.
Choose on before hand the path along which the unit is to be
brought in.
Move this unit as originally package as possible.
When lifting the unit , always use protectors to prevent belt
damage and pay attention to the position of the unit’s centre
of gravity.
1
2
3
4
INDOOR UNIT INSTALLATION
5.
5.1 Installation place
(Refer to Fig. 5-1, Fig. 5-2 and Table 5-1 for specification).
The indoor unit should be installed in a location that meets
the following requirements:
There is enough room for installation and maintenance.
The ceiling is horizontal, and its structure can endure the weight
of the indoor unit.
The outlet and the inlet are not impeded, and the influence of
external air is the least.
The air flow can reach throughout the room.
CAUTION
Keep indoor unit, outdoor unit, power supply wiring and
transmission wiring at least 1 meter away from televisions and
radios. This is to prevent image interference and noise in those
electrical appliances. (Noise may be generated depending on the
conditions under which the electric wave is generated, even if 1
meter is kept.)
QUANTITY
SHAPE
NAME
5. Owner's manual
6. Installation manual
7. Remote controller manual
1. Remote controller
(on some models)
2. Remote controller holder
(on some models)
4. Alkaline dry batteries (AM4)
1
1
2
2
1
1
Remote controller & Its Holder
Others
3. Mounting screw(ST2.9×10-C-H)
1
The connecting pipe and drainpipe could be extracted out
easily.
There is no direct radiation from heaters.
Fig.5-1
5.2 Install the main body
B
E. Connecting point of
refrigerant pipe
(D. gas side)
D. Connecting point of
refrigerant pipe
(E. Liquid side)
Drain point
Fig. 5-2
C
D
Hook
Installing Ø10 hanging screw bolts. (4 bolts)
Please Refer to Fig.5-3 and Fig.5-4 for the hanging screw
bolts distance
Evaluate the ceiling construction and please install with Ø10
hanging screw bolts.
The handling to the ceiling varies from the constructions,
consult the construction person for the specific condition.
1