89
Note:
When the maximum wind speed of the last 4s is >=5m/s, the wind speed is
detected by 1s; when the maximum wind speed of the last 4s is >=3m/s and
less than 5m/s, the wind speed is detected by 2s; when the maximum wind
speed of the last 4s is <3m/ s, the wind speed is detected by 4s.
The wind speed reading will be a real-time value (The latest sampling data
will be reporting to the receiver).
The wind gust reading will be the max wind speed in the past 28s.
When the wind speed is lower than 5m/s, the dispersion of wind direction
will increase.
Indoor sensor
Specification
Temperature range
-10°C – 60°C (14°F - 140°F)
Temperature resolution
0.1°C, or 0.1°F
Humidity range
10% ~ 99%
Humidity resolution
1%
Barometric pressure range
300 – 1,100 hPa (8.85 – 32.5 inHg)
Barometric pressure accuracy
± 3 hPa in 700 – 1,100 hPa range
Barometric pressure resolution
0.1 hPa (0.01 inHg)
Sensor reporting interval
48 seconds
Alarm Duration
120 seconds
Table 8: Indoor sensor specification
Power
Specification
Base station/console
5V DC Adapter (included)
Indoor sensor
2 x AA 1.5 Alkaline batteries (not included)
Rain gauge sensor
1 x AA 1.5V LR6 Alkaline (not included), or
1 x AA 1.5V Lithium battery (not included)
Anemometer sensor
Solar panel (built-in): 6.5V/4mA
Anemometer sensor
(backup)
2 x AA 1.5V Lithium battery (not included)
Table 9: Power specification