86
Problem
Solution
it from the rest of the sensors). The LED next to the battery
compartment will flash according to the reporting time on
the specifications. If the LED is not flashing as that…
Replace the batteries in the sensor.
If the batteries were recently replaced, check the polarity. If
the sensor is flashing normally, proceed to the next step.
There may be a temporary loss of communication due to
reception loss related to interference or other location
factors,
or the batteries may have been changed in the sensor and
the console has not been reset. The solution may be as
simple as
powering down and up the console
.
Replace the batteries in the sensor.
With the sensor and console 10 feet away from each other,
remove AC power from the display console and wait 10
seconds. Re-connect power.
Temperature sensor reads too
high in the day time.
Make certain that the sensor is not too close to heat
generating sources or strictures, such as buildings,
pavement, walls or air conditioning units.
Use the calibration feature to offset installation issues
related to radiant heat sources.
Absolute pressure does not
agree with official reporting
station
You may be viewing the relative pressure, not the absolute
pressure.
Select the absolute pressure. Make sure you properly
calibrate the sensor to an official local weather station.
Reference Section 4.9.19 for details.
Rain gauge reports rain when
it is not raining
An unstable mounting solution (sway in the mounting pole)
may result in the tipping bucket incorrectly incrementing
rainfall. Make sure you have a stable, level mounting
solution.
Data not reporting to
Wunderground.com
1. Confirm your password is correct. It is the
password you registered on Wunderground.com.
Your Wunderground.com password cannot begin
with a non-alphanumeric character (a limitation of
Summary of Contents for HP2553