background image

16 

BUTTONS AND FUNCTIONS 

Works both if the sensor is covered or not for children and elderly usage, also 

works when child seat is used. 

Press once to start child cleansing, regular cleansing  time is 90 seconds  and  warm 

air-drying  is  240  seconds.  Press  again  to  activate  pulsate  cleansing,  again  to  stop 

pulsate cleansing. 

Child function: by default, water temperature: level 3,  nozzle location: level 5, water 

pressure: level 2, dryer temperature: level 2. 

Note: when child function is on, all the function will be disabled until child cleansing is 

finished. (Except child clean button and stop button). 

Works when user is sitting on the unit and seat sensor is covered. 

Press once to start rear cleansing, regular cleansing time is 90 seconds and warm air-

drying is 240 seconds, press again within 90 seconds to activate pulsate cleansing, 

again to stop pulsate cleansing. 

After adjusting user preferences, press and hold setting button for 4 seconds, when 

top  light  indicator  and  the  fifth  function  light  indicator  starts  to  flash,  rear  cleansing 

preference has been set. 

Works when user is sitting on the unit and seat sensor is covered. 

Press  once  to  initiate  warm  air  drying,  regular  drying  time  is  240  seconds, 

corresponding light indicator will display current temperature setting. Press wind temp 

button to switch between temperature settings. 

Works when user is sitting on the unit and seat sensor is covered. 

Press once to start front cleansing, regular cleansing  time is 90 seconds and warm 

air-drying is 240 seconds, press again within 90 seconds to activate pulsate cleansing, 

again to stop pulsate cleansing. 

After adjusting user preferences, press and hold setting button for 4 seconds, when 

top light indicator and the fifth function light indicator starts to flash, female cleansing 

preference has been set. 

Press once to start user setting function which regular cleansing time is 90 seconds 

and  warm  air-drying  is  240  seconds.  (Water  temperature,  nozzle  position,  water 

pressure and dryer temperature will process by user’s setting). press again within 90 

seconds to activate pulsate cleansing, again to stop pulsate cleansing.

 

Press  BACK  button  and  FRONT  button  to  control  nozzle  position.  1  light  indicates 

minimum nozzle position, and 5 lights indicate maximum nozzle position. 

When in auto-setting mode, press BACK button to turn OFF and FRONT button to turn 

ON selected function. 

Press once to stop function which is running and switch to standby mode. Press and 

hold button for 4 seconds, all the light indicators will light up for 3 seconds then all the 

function will be reset. 

Press once to turn on hot and cold massage function. Press again to turn it off. 

Hot and cold massage function: the massage which water temperature will alternate 

between high and low in one cleansing cycle. 

Press to switch between water pressure settings. 

○○○○○: 0 light on

- no water pressure activates.

●●●●●: 5 lights on

- 0.9 L/min or 0.24 gal/min

Child Mode

Rear Wash

Air Dry

Front Wash

User Setting

Back/Off

Front/On

Stop

Hot/Cold massage

Water Pressure

Summary of Contents for TitanDT300 2050

Page 1: ...TITANDT300 2050 USER MANUAL Ecoway 174 Torbay Rd L3R 1G6 Markham Ontario www eco way ca service eco way ca 1 833 3ECOWAY 1 833 332 6929 ...

Page 2: ... and bowl unit 9 Water supply 9 Seal the bowl unit 10 Connect power cord 10 Checklist and trial run 11 NAMES OF PARTS 12 WHAT S IN THE BOX 13 FUNCTIONS OVERVIEW 13 SIDE BUTTON OPERATION 14 When user is sitting on the unit 14 When user is not sitting on the unit 14 REMOTE CONTROL OPERATION 15 CUSTOMIZING THE TITANDT300 18 MAINTENANCE 19 SPECIFICATIONS 20 ...

Page 3: ...y Children should be supervised to ensure that they do not play or tamper with the appliance WARNING DO NOT IMMERSE Doing so may cause electrical shock Do not get any water or cleaning solution on the top of unit or power plug Doing so may cause fire electric shock burns or short circuiting Doing so may cause the product to crack resulting in injury or water damage Never disassemble repair or alte...

Page 4: ...ause condensation resulting in a fire electrical shock burn or short circuiting Do not do anything that may damage the power cord power plug Do not strike yank twist excessively bend damage alter or heat the power cords Also do not place anything heavy on bind or pinch the power cords Using a damaged power cord may result in a fire electrical shock burn or short circuiting Do not use a loose or fa...

Page 5: ...y to form on the surface of this product When using the product in a bathroom install a fan or ventilation port and ensure good air flow through the bathroom Failure to do so may cause fire or electrical shock Always connect the TitanDT 300 to the cold water supply Connecting to hot water supply may result in burns and equipment damage Make sure that a properly grounded 3 prong outlet has been ins...

Page 6: ...eliminary studies in females suggest that overuse of continuous spraying can increase the possibility of vaginal mucosa drying and potential reduction in desirable microbial organisms Although these studies have not been validated please consult your healthcare provider for concerns regarding whether these circumstances may apply to you More importantly if you are an individual suffering from any ...

Page 7: ...ry When cleaning or maintaining the plastic parts top unit etc or the water supply hose use a kitchen cleaner diluted with water Do not use any of the following Toilet cleaner household cleaner benzene paint thinner powdered cleanser or nylon scrubbing pads These items may damage or crack the plastic and cause injury or malfunction These items could damage the water supply hose and cause a water l...

Page 8: ...ay cause a water leak If the bowl unit is clogged disconnect the power plug and remove the clog If the auto flush Is functioning it could make the wastewater in the bowl unit overflow and may result in water damage Use commercially available tools that are made for unclogging the bowl unit to remove the clogging Always flush even after just urinating Failure to do so may cause inadequate flushing ...

Page 9: ...essure 0 1MPa 1 0kgf cm2 flow of water is greater or equal to 20L or 5 3 gallon per minute Unit may not function well if water pressure fails to reach this level Check the water pressure open the valve and let the water run into a bucket for 15 seconds if water in the bucket is more than 4L minimum water pressure is met INSTALLATION DRAWING PLAN CAUTION The drawing plan is not the actual scale of ...

Page 10: ...ary 3 Turn on the valve for a minute to keep inside of valve clean 4 Turn off the valve connect the filter and the unit with pipe turn on the valve again carefully check for leakage Filter screen should be cleaned with clear water every three months Steps to clean filter screen Turn off the valve unscrew filter screen carefully rinse with clean water Pipe and valve could be different from above graphic ...

Page 11: ...least 24 hours Follow instructions of specific sealant used for installation CONNECT POWER CORD 1 Power cord must be connected to a 120V 60Hz 16A grounded GFI Ground Fault Circuit Interrupter power socket 2 Wait for the unit to finish self inspection after connected It is normal that user see side button flash blue light nozzle stretch out machine engage on and flash sound 3 User should do a trial run...

Page 12: ... buttons place one hand on the sensor area on the seat to activate certain cleansing functions place a plastic sheet between the seat and toilet bowl to avoid water spraying out of the bowl Front and rear wash Massage Water temperature Water pressure Nozzle position Nozzle self cleansing Air dryer Air temperature Seat temperature Flushing A trial run is mandatory for safety purposes if any malfunc...

Page 13: ...12 NAMES OF PARTS There could be minor difference between actual product and above graphic due to production batches 305mm 12 ...

Page 14: ...sh Stainless steel nozzle Self cleansing nozzle Pre rinse before use Overheat protection Low temperature burn protection Silent self closing seat and cover Fire retardant seat Pressure resistance seat Power saving mode Power leak protection IPX 4 resistance Power outage flush Power outage memory Warm air drying Heated seat Adjustable water temperature Adjustable water pressure Adjustable air tempe...

Page 15: ... seconds by default When user is seated on the unit press once to start warm air drying for 240 seconds When other functions are in process press once to stop on going function When the unit connected to power supply press and hold button to begin manual flushing Note if the unit is not connected to the power supply press and hold button to begin manual flushing by Lithium battery Lithium battery ...

Page 16: ...REMOTE CONTROL OPERATION 0 09 0 0 0 0 0 5 复 包 Note Remote control could be different from above graphic due to production batches please refer to actual product 15 ...

Page 17: ...once to start front cleansing regular cleansing time is 90 seconds and warm air drying is 240 seconds press again within 90 seconds to activate pulsate cleansing again to stop pulsate cleansing After adjusting user preferences press and hold setting button for 4 seconds when top light indicator and the fifth function light indicator starts to flash female cleansing preference has been set Press once...

Page 18: ...e is at room temperature 1 light on approximately 32 C or 89 F 2 lights on approximately 34 C or 93 F 3 lights on approximately 36 C or 96 F 4 lights on approximately 38 C or 100 F 5 lights on approximately 40 or 104 Press once to initiate flush Please see next page on how to customize your TitanDT300 with auto settings Press once to turn ON the unit Press and hold the button for 2 seconds to turn ...

Page 19: ...d and seat are open 3 Flush timing Turn flush timing ON or OFF When ON unit flushes when warm dryer starts When OFF unit flushes when user leaves the seat 4 Press STOP button or wait for 18 seconds to save and exit auto setting mode Note press and hold stop button for 4 seconds to reset all settings to factory default REMOTE CONTROL TROUBLESHOOTING If the remote control is not responding 1 Check if t...

Page 20: ...nozzle with a soft cloth or brush with toothbrush 2 The cleansing schedule is 90 seconds the nozzle will be static in first 70 second and will move back and forth in last 20 seconds Nozzle will retract back to the unit after cleansing Repeat the process if necessary 3 Warning do not apply force by pulling pushing or attempt to bend the nozzle this w ill result in damage or electrical shock Cleaning...

Page 21: ... Water level sensor Warm air dryer Warm air temperature 2 Adjustable temperature range room temperature to 60 C about 40 C to 60 C about 104 F to 140 F Airflow speed Approx 4 8m s Approx 15 75 ft min Heater capacity 200 W 5 Safety device Temperature fuse Heated seat Surface temperature Adjustable temperature from 32 C to 40 C About 89 F to 104 F Heater capacity 40 W 7 Safety device Temperature fuse...

Reviews: