background image

22

ECOWATER

S Y S T E M S

Troubleshooting

MANUALLY INITIATED ELECTRONIC

DIAGNOSTICS

Use the following procedures to advance the softener

through the recharge cycles to check operation.
Remove the top cover 

by unlocking the tabs and tilting

it forward, 

to observe cam and switch operation during

valve rotation.

1

. Press and hold for 3 seconds the SELECT button,

until one of the screens shown in Figure 48 is dis-

played.

FIG. 48

2

. The last 2 digits in the display indicate POSITION

switch operation as follows:

FIG. 46

AUTOMATIC ELECTRONIC DIAGNOSTICS

This softener has a self-diagnostic function for the

electrical system.  The computer monitors electronic

components and circuits for correct operation.  If a

malfunction occurs, an error code appears in the dis-

play.

The chart below shows the error codes that could

appear, and the possible malfunctions for each code.

Code

Possible Problems

Err01 Motor, Valve Position Switch
Err03 Motor, Valve Position Switch, Wire Harness
Err04 Valve Position Switch
Err05 Electronic Control Board (PWA)

While an error code appears in the display, all buttons

are inoperable except the SELECT button.  SELECT

remains operational so the service person can per-

form the Manually Initiated Electronic Diagnostics to

further isolate the problem.

TO REMOVE AN ERROR CODE:

1

. Unplug the power supply.

2

. Correct the problem.

3

. Plug the power supply back in.

4

. Wait for at least 8 minutes while the timer operates

the valve through an entire cycle.  The error code

will return if the problem was not corrected.

Switch

Correct Switch

Displays

Valve Cycle Status

–  –

Valve in service, fill, brining,

backwash or fast rinse position.

–  

P

Valve rotating from one position

to another.

3

. Use the RECHARGE button to 

manually advance

the valve into each position and check correct switch

operation (See Figures 50-54).

4

. While in this diagnostic screen, the following infor-

mation is available and may be beneficial for vari-

ous reasons.  This information is retained by the

computer from the first time electrical power is

applied to the electronic controller.

   

a

. Press the 

á

UP button to display the number of

days this electronic control has had electrical

power applied.

   

b

. Press the 

â

DOWN button to display the num-

ber of automatic or manual recharges initiated

by this electronic control since the model code

number was entered.

5

. Press the SELECT button and hold in for 3 sec-

onds until the model code shows in the display.

See the table on Page 13 for model codes.  If the

wrong number shows, the softener will operate on

incorrect configuration data.

6

. To change the code number - Press the 

á

UP or

â

DOWN button until the correct code shows.

continued on next page

Position markers

(valve in service)

CAM

MOTOR

FIG. 47

Summary of Contents for ESS1102XR32

Page 1: ...t Paul MN 55164 0420 www ecowater com Designed Engineered Assembled in the U S A System tested and certified by the Water Quality Association against CSA B483 1 System tested and certified by NSF Inte...

Page 2: ...ive 2002 96 EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic Equipment WEEE require ments This directive or similar laws are in place...

Page 3: ...oduct This warranty is called the Perfect Ten and extends the three year warranty on the electronic FACE PLATE WIRING HARNESS DRIVE MOTOR POWER SUPPLY POWER CORD SENSOR HOUSING and MICRO SWITCH ES to...

Page 4: ...move clear water iron is substantiated by independent laboratory test data State of Wisconsin requires additional treatment if water supply con tains greater than 5 ppm clear water iron u Canada worki...

Page 5: ...5 ECOWATER S Y S T E M S Dimensions FIG 1 32 BRINE TANK MEDIA TANK IN OUT 36 9 16 3 3 8 14 16 14 16 56 5 8 49 3 4...

Page 6: ...tion plumbing wiring etc are as well protected from the elements contamination vandalism etc as when installed indoors Keep the softener out of direct sunlight The sun s heat may soften and distort pl...

Page 7: ...sed and media in that order Be sure the distributor remains centered Use water sparingly to speed flow through the funnel It may become necessary to siphon water from the bottom of distributor if tank...

Page 8: ...ET SOFT WATER FROM SOFTENER OUTLET Hard Water to Outside Faucets EcoWater Bypass Valve 1 1 2 Air Gap 1 1 2 Air Gap 1 1 2 Air Gap LAUNDRY TUB SUMP STAND PIPE To standpipe sump laundry tub or other suit...

Page 9: ...in place 3 COMPLETE PLUMBING TO AND FROM THE SOFTENER Using the Typical Installation Illustration on page 8 as a guide observe all of the following cautions while you connect inlet and outlet plumbin...

Page 10: ...Use high quality thick wall hose that will not easily kink or collapse The softener will not backwash properly if water cannot exit this hose during recharges c Tie or wire the hose in place at the d...

Page 11: ...ntroller Follow the steps on Pages 13 14 for softeners or Page 16 for filters to program the electronic controller with basic operating information such as time and water hardness After completing the...

Page 12: ...softener begins recharging This recharge draws the sanitizing bleach into and through the softener Any air remaining in the unit is purged to the drain d After the recharge has completed fully open a...

Page 13: ...time Up moves the display ahead down sets the time back Be sure AM or PM is correct NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance 3 When...

Page 14: ...rges SET NUMBER OF PEOPLE If a hardness level was set in the previous step you will set the Number of People in the household 1 Press the UP or DOWN buttons to set the number of people The factory def...

Page 15: ...ows in the display 2 Press the SELECT button four times and bA will appear in the display followed by the current back wash time in minutes flashing 3 Use the UP or DOWN buttons to set the number of m...

Page 16: ...correct time is displayed press the SELECT button and the display will change to show the Recharge screen SET DAYS BETWEEN RECHARGES This setting is the number of days the filter will go between rech...

Page 17: ...emaining screens and return to the normal run time of day display ADJUSTABLE FAST RINSE TIME 1 Press and hold the SELECT button until 000 shows in the display 2 Press the SELECT button five times and...

Page 18: ...ure 36 3 Use the UP or DOWN buttons to display the desired selection then press the SELECT button If you selected anything other than CF the display will return to the normal run time of day screen If...

Page 19: ...time of day screen See Fig 41 will then be dis played Remember to do this or the unit will not recharge and you will soon have hard unfiltered water FIG 43 NORMAL OPERATION During normal operation the...

Page 20: ...ed SALT WITH IRON REMOVING ADDITIVE Some salts have an additive to help a water softener handle iron in the water supply Although this may help keep the resin bed clean it may also release corrosive f...

Page 21: ...ft out the screen support and screen Then remove the nozzle venturi disc gas ket and flow plug Wash the parts in warm soapy water and rinse in fresh water Be sure to clean both the top and bottom of t...

Page 22: ...late the problem TO REMOVE AN ERROR CODE 1 Unplug the power supply 2 Correct the problem 3 Plug the power supply back in 4 Wait for at least 8 minutes while the timer operates the valve through an ent...

Page 23: ...continued from previous page 7 To return to the present time display press the SELECT button If the model code was changed make all controller settings NOTE If the electronic control is left in a diag...

Page 24: ...24 SYSTEM EXPLODED VIEW ECOWATER S Y S T E M S Repair Parts Valve Assembly See Pages 26 27 for parts 5 6 4 3 2 1 16 17 7 8 9 10 12 11 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29...

Page 25: ...Resin 1 cu ft standard mesh Key No Part No Description 16 7274286 Rim 17 7355692 Shroud Mineral Tank 18 7310210 Brine Valve Assembly 19 7327568 Float Stem Guide Assembly 20 7355731 Brine Tank 21 73557...

Page 26: ...S Y S T E M S Repair Parts VALVE EXPLODED VIEW 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 75 76 65 77 78 80 79 81 82 83 Wear Strip Seal Cross section View 84 85 86 87 88 89 90 54 70 71 72...

Page 27: ...Nos 71 73 71 0507369 Installation Nut 2 req 72 0507615 Installation Tube 3 4 2 req 73 7170335 Washer 2 req Key No Part No Description 74 7278442 Installation Adaptor 3 4 single 2 req 7336606 Installa...

Reviews: