background image

13

ECOWATER

S Y S T E M S

Programming the Electronic Controller

FIG. 14

UP button

DOWN button

Display

RECHARGE button

SELECT button

CONTROLLER SETTINGS REQUIRED

upon installation, and after an extended power outage.
When the power supply is plugged into the electrical

outlet, a model code (example: ST31) and a version

number (example: J3.8), are briefly shown in the dis-

play.  For softener or tannin filter use, you must select

the correct model code, as shown below.

SET MODEL CODE

1

. Press and hold for 3 seconds the SELECT button,

until the display shows “000 - -“ (See Figure 15).

3

. Press the  

á

UP or 

â

DOWN buttons to select

the correct model code for softener or tannin filter

use.  See the table below.

FIG. 17

2

. Press the 

á

UP or 

â

DOWN buttons to set the

present time.  Up moves the display ahead; down

sets the time back.  Be sure AM or PM is correct.

NOTE:

Press buttons and quickly release to slowly

advance the display.  Hold the buttons down

for fast advance.

3

. When the correct time is displayed, press the

SELECT button, and the display will change to

show the “Hardness” screen.

continued on next page

4

. With the correct model code displayed, press the

SELECT button to restart the controller.  Follow the

programming steps below to set the timer for sof-

tener use.  

If you are using the unit as a tannin

filter, go to the programming steps on Page 16.

SET PRESENT TIME OF DAY

1

. If the words “PRESENT TIME" do not show in the

display, press the SELECT button several times

until they do.

Model Code Amount of Resin

Tank Size

ST31

1 cu. ft.

10” x 47”

ST39

1-1/4 cu. ft.

10” x 47”

STAn

use for tannin filters

2

. Press and hold for 3 seconds the SELECT button

once again until a model code appears in the dis-

play.

FIG. 15

FIG. 16

Summary of Contents for ESS1102XR32

Page 1: ...t Paul MN 55164 0420 www ecowater com Designed Engineered Assembled in the U S A System tested and certified by the Water Quality Association against CSA B483 1 System tested and certified by NSF Inte...

Page 2: ...ive 2002 96 EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic Equipment WEEE require ments This directive or similar laws are in place...

Page 3: ...oduct This warranty is called the Perfect Ten and extends the three year warranty on the electronic FACE PLATE WIRING HARNESS DRIVE MOTOR POWER SUPPLY POWER CORD SENSOR HOUSING and MICRO SWITCH ES to...

Page 4: ...move clear water iron is substantiated by independent laboratory test data State of Wisconsin requires additional treatment if water supply con tains greater than 5 ppm clear water iron u Canada worki...

Page 5: ...5 ECOWATER S Y S T E M S Dimensions FIG 1 32 BRINE TANK MEDIA TANK IN OUT 36 9 16 3 3 8 14 16 14 16 56 5 8 49 3 4...

Page 6: ...tion plumbing wiring etc are as well protected from the elements contamination vandalism etc as when installed indoors Keep the softener out of direct sunlight The sun s heat may soften and distort pl...

Page 7: ...sed and media in that order Be sure the distributor remains centered Use water sparingly to speed flow through the funnel It may become necessary to siphon water from the bottom of distributor if tank...

Page 8: ...ET SOFT WATER FROM SOFTENER OUTLET Hard Water to Outside Faucets EcoWater Bypass Valve 1 1 2 Air Gap 1 1 2 Air Gap 1 1 2 Air Gap LAUNDRY TUB SUMP STAND PIPE To standpipe sump laundry tub or other suit...

Page 9: ...in place 3 COMPLETE PLUMBING TO AND FROM THE SOFTENER Using the Typical Installation Illustration on page 8 as a guide observe all of the following cautions while you connect inlet and outlet plumbin...

Page 10: ...Use high quality thick wall hose that will not easily kink or collapse The softener will not backwash properly if water cannot exit this hose during recharges c Tie or wire the hose in place at the d...

Page 11: ...ntroller Follow the steps on Pages 13 14 for softeners or Page 16 for filters to program the electronic controller with basic operating information such as time and water hardness After completing the...

Page 12: ...softener begins recharging This recharge draws the sanitizing bleach into and through the softener Any air remaining in the unit is purged to the drain d After the recharge has completed fully open a...

Page 13: ...time Up moves the display ahead down sets the time back Be sure AM or PM is correct NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance 3 When...

Page 14: ...rges SET NUMBER OF PEOPLE If a hardness level was set in the previous step you will set the Number of People in the household 1 Press the UP or DOWN buttons to set the number of people The factory def...

Page 15: ...ows in the display 2 Press the SELECT button four times and bA will appear in the display followed by the current back wash time in minutes flashing 3 Use the UP or DOWN buttons to set the number of m...

Page 16: ...correct time is displayed press the SELECT button and the display will change to show the Recharge screen SET DAYS BETWEEN RECHARGES This setting is the number of days the filter will go between rech...

Page 17: ...emaining screens and return to the normal run time of day display ADJUSTABLE FAST RINSE TIME 1 Press and hold the SELECT button until 000 shows in the display 2 Press the SELECT button five times and...

Page 18: ...ure 36 3 Use the UP or DOWN buttons to display the desired selection then press the SELECT button If you selected anything other than CF the display will return to the normal run time of day screen If...

Page 19: ...time of day screen See Fig 41 will then be dis played Remember to do this or the unit will not recharge and you will soon have hard unfiltered water FIG 43 NORMAL OPERATION During normal operation the...

Page 20: ...ed SALT WITH IRON REMOVING ADDITIVE Some salts have an additive to help a water softener handle iron in the water supply Although this may help keep the resin bed clean it may also release corrosive f...

Page 21: ...ft out the screen support and screen Then remove the nozzle venturi disc gas ket and flow plug Wash the parts in warm soapy water and rinse in fresh water Be sure to clean both the top and bottom of t...

Page 22: ...late the problem TO REMOVE AN ERROR CODE 1 Unplug the power supply 2 Correct the problem 3 Plug the power supply back in 4 Wait for at least 8 minutes while the timer operates the valve through an ent...

Page 23: ...continued from previous page 7 To return to the present time display press the SELECT button If the model code was changed make all controller settings NOTE If the electronic control is left in a diag...

Page 24: ...24 SYSTEM EXPLODED VIEW ECOWATER S Y S T E M S Repair Parts Valve Assembly See Pages 26 27 for parts 5 6 4 3 2 1 16 17 7 8 9 10 12 11 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29...

Page 25: ...Resin 1 cu ft standard mesh Key No Part No Description 16 7274286 Rim 17 7355692 Shroud Mineral Tank 18 7310210 Brine Valve Assembly 19 7327568 Float Stem Guide Assembly 20 7355731 Brine Tank 21 73557...

Page 26: ...S Y S T E M S Repair Parts VALVE EXPLODED VIEW 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 75 76 65 77 78 80 79 81 82 83 Wear Strip Seal Cross section View 84 85 86 87 88 89 90 54 70 71 72...

Page 27: ...Nos 71 73 71 0507369 Installation Nut 2 req 72 0507615 Installation Tube 3 4 2 req 73 7170335 Washer 2 req Key No Part No Description 74 7278442 Installation Adaptor 3 4 single 2 req 7336606 Installa...

Reviews: