6
Water Softener Programming
ECOWATER
S Y S T E M S
English
12 OR 24 HOUR CLOCK
The timer has been factory
preset to display a 24 hour
clock. If you prefer, you
may change this to display a
12 hour clock.
1
. Press and hold the
SELECT button until “000
- -” shows in the display.
2
. Press the SELECT button
three times and “24 hr"
will flash in the display.
3
. Use the
â
DOWN button
to change to a 12 hour
clock display.
4
. Press the SELECT button
several times to advance
through the remaining screens and return to the nor-
mal operation (time of day) display.
5
. To change back to a 24 hour clock, follow Steps 1
through 4, above, except use the
á
UP button in
Step 3.
ADJUST BACKWASH TIME AND RINSE
TIME
The timer can be changed
to allow different backwash
and fast rinse times, if so
desired. Each of these can
be adjusted from 0 to 30
minutes.
1
. Press and hold the
SELECT button until “000
- -” shows in the display.
2
. Press the SELECT button
four times and “bA- " will
flash in the display.
3
. Use the
á
UP or
â
DOWN buttons to set the
number of minutes
desired for backwash.
4
. Press the SELECT button again and “Fr- " will flash
in the display.
5
. Use the
á
UP or
â
DOWN buttons to set the num-
ber of minutes desired for fast rinse.
6
. Press the SELECT button to return to the normal
operation (time of day) display.
AUXILIARY OUTPUT
The electronic controller’s auxiliary output can be used
to operate a chlorine generator. It provides a 24V DC,
up to 500 mA, current from terminal J4 on the electronic
control board. This current is on during the brine draw
portion of the softener’s recharge cycle.
POWER OUTAGE MEMORY
If electrical power to the softener’s control is lost, inter-
nal memory will maintain most settings such as the
hardness and recharge time. However, unless the
power outage was very brief, the clock’s present time
will need to be reset. During a power outage, the dis-
play will be blank and the softener will not recharge.
When electrical power is restored:
1
. Check the display.
2a
. If the present time is displayed steadily (not flash-
ing), the controller did not lose time and you do not
need to reset the clock.
2b
. If a time is flashing in the display, then the clock
needs to be reset to the correct present time. See
“Set Present Time of Day” on page 4. The flashing
display is to remind you to reset the clock. If you
do not reset the clock, then recharges will most like-
ly occur at the wrong time of day.
NOTE:
If the softener was recharging when power was
lost, it will finish the cycle when power returns.