All work described below is in compliance with NEN 3140.
√
Check whether the proper order has been maintained for the connecting
terminals.
√
Check whether the cores have been properly tightened, 4 to 5 Nm.
√
Check whether the ground connection has been made with the supplied
grounding.
√
Check whether the cable thickness of the power cable matches the fused
current rating.
√
Check whether the charging station is tightly and properly secured.
√
Check whether the station is sufficiently waterproof.
√
Keep the immediate environment of the work area free from obstacles.
Before connecting the charging station to power, the back office
provider must be contacted to allow the software to be activated. The
unique charging station number is required for this.*
*Only applies to charging systems with registration
19. USER / INSTALLATION MANUAL
19.1 Open the cover
Proceed as follows to open the cover.
Use the included screwdriver bit to remove the screws on the bottom of the
charger. See figure 1 The cover can then be removed by sliding de cover to
the side and then upward.
To close the cover, perform this procedure in the reverse order.