Ecostrad F0606 Instruction Manual Download Page 9

 

Wall Mounting Instructions 

These instructions apply to wall mounting only. Turn to page 10 for ceiling 

mounting instructions.  
If the device is being fitted in a bathroom, the unit must not be plugged in. The 

plug should be removed and the unit hardwired into a fused spur. This is a job for 

a qualified electrician. 

1.

 

Choose the mounting position, respecting the 
minimum distances from surrounding walls, ceilings 
or fixed objects listed in the table opposite. 
Minimum distances must be observed. Mounting 
closer than recommended creates a fire risk.  

2.

 

Stick the drilling template on the wall. Drill the holes 
with an 8mm rotary bit. 

 

3.

 

Push the wall plugs (C) into the holes. Insert the screws (B) into the wall plugs. 
The screws should protrude approx. 5mm from the plugs.  

4.

 

Hang the heating panel on the screws.  

 

5.

 

Slide the panel across so that the screws lock into their correct position in the 
bracket, as pictured below:  

 

Minimum distances  

Front 

300mm 

Left 

100mm 

Right 

100mm 

Top  

500mm 

Summary of Contents for F0606

Page 1: ...1 Ecostrad Opus Infrared Heating Panel Ratings 220 240 V 50 Hz Class I IP54...

Page 2: ...s clothes etc above or directly in front of the device To avoid overheating and fire hazards the device must not be covered Hot surface This symbol located on the device indicates that its surfaces ar...

Page 3: ...1 About the Device 2 Warnings Precautions 3 Technical Information 4 Supplied Parts 5 Device Structure 6 Installation 7 Troubleshooting 8 Maintenance Servicing 9 Storage 10 ErP Ecodesign Information 1...

Page 4: ...ilure to follow the warnings and instructions may result in electric shock fire serious injury or all of the above Save all warnings and instructions for future reference Warning Do not ceiling mount...

Page 5: ...sitive skin and people under the influence of alcohol drugs or sleeping pills Remove both protective films on the front and on the back before using Be sure the usage voltage is between 220 240V 50Hz...

Page 6: ...housing and pull Switch the device off and disconnect the power cable from the mains socket when the device is not in use Do not under any circumstances use the device if you detect damage to the main...

Page 7: ...A Mounting Type F0606 595 x 595 350 230V 50Hz 1 5 Wall only F0706 705 x 605 450 2 0 Wall only F1006 1005 x 605 580 2 5 Wall only F1207 1205 x 755 900 3 9 Wall only F1209 1205 x 905 1100 4 8 Wall only...

Page 8: ...nting kits are available through the supplier Kits are available for both direct and suspended installation Purchase a suitable kit before attempting ceiling mounted installation 5 Device Structure Co...

Page 9: ...rrounding walls ceilings or fixed objects listed in the table opposite Minimum distances must be observed Mounting closer than recommended creates a fire risk 2 Stick the drilling template on the wall...

Page 10: ...ct Method This method should only be used with panels designed for ceiling mounting when the kit below has been purchased Ecostrad Ceiling Mounting Kit 1 Drill four holes on the ceiling positioned as...

Page 11: ...ws to the end tightly This is important for a secure fitting 3 Take off all four plastic caps from the mounting bars on the back of the panel Slide the panel onto the hanging brackets as per the diagr...

Page 12: ...been purchased Ecostrad Suspended Mounting Kit Components 1 x Heating Panel A 4 x Panel Caps B 4 x Wire Caps C 4 x Ceiling Lock Screws D 4 x Ceiling Lock Heads E 4 x Long Screws F 4 x Short Screws G 4...

Page 13: ...gh wire caps C Screw C onto B 3 Drill four 6mm holes in the ceiling using a 6mm drill bit Fix the four expansion plugs H into the holes 4 Insert the four long screws F into ceiling lock heads E and sc...

Page 14: ...adjust the length of the suspension wire hold down the catch on the ceiling lock heads and feed the wire through the gap in the lock head Release the catch and the wire will lock automatically in you...

Page 15: ...mperature Two possible causes 1 Voltage is too low 1 Contract an electrician to install a voltage regulator 2 The room where the panel is hung is very cold 2 This is normal Give the panel plenty of ti...

Page 16: ...in an upright position out of direct sunlight Store in a dry environment protected from frost and heat Protect against dust using a cover if necessary To prevent damage do not store other objects on t...

Page 17: ...lus week timer yes Other control options multiple selections possible room temperature control with presence detection no room temperature control with open window detection no with distance control o...

Reviews: