3 | Technical Information  

 
Heating element 

Carbon crystal  

Heating method 

Far infrared heating  

Voltage  

220-240V/50Hz 

Surface temperature 

Wall panels: approx. 85-95 °C 

Ceiling panels: approx. 90-105 °C 

Body material  

Aluminium  

IP rating 

IP54 (excluding plug) 

Overheat protection 

Yes 

Power cable length 

1.9m 

 

Model Specifications  

Model 

Size (mm) 

Power 
(W) 

Voltage / 
Frequency 

Rated 
Current (A) 

Mounting 
Type 

F0606 

595 x 595 

350 

230V / 50Hz 

1.5 

Wall only 

F0706 

705 x 605 

450 

2.0 

Wall only 

F1006 

1005 x 605 

580 

2.5 

Wall only 

F1207 

1205 x 755 

900 

3.9 

Wall only 

F1209 

1205 x 905 

1100 

4.8 

Wall only 

F0606-C 

595 x 595 

270 

1.2 

Ceiling or wall 

F0706-C 

705 x 605 

320 

1.4 

Ceiling or wall 

F1006-C 

1005 x 605 

450 

2.0 

Ceiling or wall 

F1207-C 

1205 x 755 

700 

3.0 

Ceiling or wall 

F1209-C 

1205 x 905 

800 

3.5 

Ceiling or wall 

Warning

 

Do not ceiling mount panels designed for wall mounting only. 

Use of panels in unspecified locations can cause panels to overheat and poses a 
fire risk. 

 

Summary of Contents for F0606

Page 1: ...1 Ecostrad Opus Infrared Heating Panel Ratings 220 240 V 50 Hz Class I IP54...

Page 2: ...s clothes etc above or directly in front of the device To avoid overheating and fire hazards the device must not be covered Hot surface This symbol located on the device indicates that its surfaces ar...

Page 3: ...1 About the Device 2 Warnings Precautions 3 Technical Information 4 Supplied Parts 5 Device Structure 6 Installation 7 Troubleshooting 8 Maintenance Servicing 9 Storage 10 ErP Ecodesign Information 1...

Page 4: ...ilure to follow the warnings and instructions may result in electric shock fire serious injury or all of the above Save all warnings and instructions for future reference Warning Do not ceiling mount...

Page 5: ...sitive skin and people under the influence of alcohol drugs or sleeping pills Remove both protective films on the front and on the back before using Be sure the usage voltage is between 220 240V 50Hz...

Page 6: ...housing and pull Switch the device off and disconnect the power cable from the mains socket when the device is not in use Do not under any circumstances use the device if you detect damage to the main...

Page 7: ...A Mounting Type F0606 595 x 595 350 230V 50Hz 1 5 Wall only F0706 705 x 605 450 2 0 Wall only F1006 1005 x 605 580 2 5 Wall only F1207 1205 x 755 900 3 9 Wall only F1209 1205 x 905 1100 4 8 Wall only...

Page 8: ...nting kits are available through the supplier Kits are available for both direct and suspended installation Purchase a suitable kit before attempting ceiling mounted installation 5 Device Structure Co...

Page 9: ...rrounding walls ceilings or fixed objects listed in the table opposite Minimum distances must be observed Mounting closer than recommended creates a fire risk 2 Stick the drilling template on the wall...

Page 10: ...ct Method This method should only be used with panels designed for ceiling mounting when the kit below has been purchased Ecostrad Ceiling Mounting Kit 1 Drill four holes on the ceiling positioned as...

Page 11: ...ws to the end tightly This is important for a secure fitting 3 Take off all four plastic caps from the mounting bars on the back of the panel Slide the panel onto the hanging brackets as per the diagr...

Page 12: ...been purchased Ecostrad Suspended Mounting Kit Components 1 x Heating Panel A 4 x Panel Caps B 4 x Wire Caps C 4 x Ceiling Lock Screws D 4 x Ceiling Lock Heads E 4 x Long Screws F 4 x Short Screws G 4...

Page 13: ...gh wire caps C Screw C onto B 3 Drill four 6mm holes in the ceiling using a 6mm drill bit Fix the four expansion plugs H into the holes 4 Insert the four long screws F into ceiling lock heads E and sc...

Page 14: ...adjust the length of the suspension wire hold down the catch on the ceiling lock heads and feed the wire through the gap in the lock head Release the catch and the wire will lock automatically in you...

Page 15: ...mperature Two possible causes 1 Voltage is too low 1 Contract an electrician to install a voltage regulator 2 The room where the panel is hung is very cold 2 This is normal Give the panel plenty of ti...

Page 16: ...in an upright position out of direct sunlight Store in a dry environment protected from frost and heat Protect against dust using a cover if necessary To prevent damage do not store other objects on t...

Page 17: ...lus week timer yes Other control options multiple selections possible room temperature control with presence detection no room temperature control with open window detection no with distance control o...

Reviews: