Excerpt from the Declaration of
Incorporation
(as defined in EC Machinery Directive 2006/42/EC for
incorporation of partly completed machinery according to
annex II, part B).
The product described on the reverse side has been
developed, constructed and produced in accordance with the
following directives:
•
EC Machinery Directive 2006/42 EC
•
EC Construction Products Directive 89/106/EEC
•
EC Low-Voltage Directive 2006/95/EC
•
EC Electromagnetic Compatibility Directive 2004/108/EC
Applied and consulted standards and specifications:
•
EN ISO 13849-1, PL “c”, Cat. 2
Safety of machinery – Safety-related parts of control
systems – Part 1: General principles
•
EN 60335-1 / 2, when applicable
Safety of electrical appliances / Operators for doors
•
EN 61000-6-3
Electromagnetic compatibility – Electromagnetic radiation
•
EN 61000-6-2
Electromagnetic compatibility – Interference immunity
Partly completed machinery as defined in the EC Directive
2006/42/EC is only intended to be incorporated into or
assembled with other machinery or other partly completed
machinery or equipment, thereby forming machinery to which
this directive applies.
This is why this product must only be put into operation after
it has been determined that the entire machine / system in
which it will be installed corresponds with the guidelines of
the EC directive mentioned above.
Any modification made to this product without our express
permission and approval shall render this declaration null and
void.
13
Technical Data
Mains voltage
230 / 240 V, 50 / 60 Hz,
Stand-by
Approx. 6 W
Mains voltage type
Y
Protection category
Only for dry rooms
Temperature range
– 20 °C to + 60°C
Automatic safety
cut-out
Is automatically taught in for both
directions separately.
End-of-travel position
cut-out / force limit
•
Self-learning
•
Wear-free, as it is designed
without mechanical switches
•
Additionally integrated run
time limit of approx. 45 s
•
Automatic safety cut-out,
readjusting at every door run.
Rated load
See data label
Pull and push force
See data label
Motor
Direct current motor with hall
sensor
Transformer
with thermal protection
Connection
technology
•
Simple screw terminal
•
Max. 1.5 mm
2
•
For internal and external
buttons with impulse
operation
Special functions
•
Operator light, 2-minute light
•
2-wire photocell can be
attached
Mechanical release
Actuated from inside with pull
cord in the event of a power failure
Remote control
With 2-button hand transmitter
RSC 2 (433 MHz) and integral
radio receiver with 6 memory
spaces
Universal fittings
For up-and-over doors and
sectional doors
Door travel speed
Approx. 10.5 cm per second
(depending on the door type, the
door size and the door leaf weight)
Airborne sound
emission of the
garage door operator
The equivalent continuous sound
pressure level of 70 dB
(A-weighted) is not exceeded at a
distance of three metres.
Operator boom
•
Extremely flat (30 mm)
•
Three-part
•
With maintenance-free,
patented toothed belt
Use
•
Exclusively for private
garages
•
For easy to move up-and-
over and sectional doors with
a door area of up to 7,125 m
2
•
Not
approved for
industrial / commercial use.
32